LabInstSourceLab instruments, testing equipment, balances, microscopes, cleanroom products, and technical sourcing support for global buyers.
Optical Emission Spectrometer for Laboratory
Laboratory Instruments

Optical Emission Spectrometer for Laboratory | RFQ Sourcing Details

Laboratory Instruments · Quote on request

This is a product procurement detail page: check specs, images, category context and related sourcing paths before sending an RFQ.

Quote on request

Product specs

CategoryLaboratory Instruments
Unitset
Sizeand Weight: Inlet pressure: 0.5MPa
typerunge device Focal length of grating: 750mm Wavelength range: 130-650nm Open spark desk All kinds of fixture for special
Powersupply: 220V±10% , 50Hz±2% Max
OriginWuxi
Warranty1 Year
AdvantageHigh Sensitive
CategoryLaboratory Instruments
AvailabilityInquiry required
Updated2026-05-31

Buyer's Digest

Use this page as a product-first sourcing checkpoint before sending an RFQ. Category: Laboratory Instruments. Confirm application fit, capacity, materials, destination, lead time and compliance requirements before comparing suppliers.

Original product description

. . Model NO.

JB-750 Detection Method Spectrophotometer Advantage High Sensitive Principle Classic Spectrometer Wavelengths UV Spectrometer Dispersive Element Interferometer Spectrometer Light Number Monochromator Certification RoHS, ISO9001, CE Customized Customized Delivery Time 14days Transport Package Wooden Case/Carton/Pallet(Depends on) Specification CE/RoHS/ISO/WSC Trademark JB Origin Wuxi HS Code Production Capacity 20sets/Month Summary JB 750 Optical Emission Spectrometer is the best assistant for rapid quantitative analysis of metallurgical furnace and metallic quality monitoring.

Its accuracy and stability meet laboratory requirements and can make measurements for dozens of matrix based on elements such as Fe,Al,Cu,Ni,Co,Ti,Mg,Zn,Sn,Pb, etc. It is widely used in steel, metallurgy, foundry and machinery for IQC, QC and OQC.

JB-750 is a design of zero fault operation, which requires little maintenance and offering h igh reliability and convenience. Features 750 mm focal length grating design with palmer type runge device which has the features of high vacuum, high resolution and high sensitivity etc. Adopt high stability digital sources.

You can choose different excitation parameters to analyze different samples which can get the best analysis results. The automation is very high which adopts high integration of the acquisition and control system.

The photomultiplier tubes from Hamamatsu which has the features of low dark current, high signal-to-noise ratio, long service life etc. It can be used for variety of bases such as Fe, Al, Cu, Co, Ni, Pb, Mg, Zn, Sn etc.

The temperature of the optical part is stable which ensure the instrument running well and reduce the requirement of the environment. The system adopts independent power supply and becomes unit which is easy to use and simple maintenance.

The computer adopts Windows 7 system and English operation software which is simple to understand.

Technical Parameter Optical System: Excitation Desk: Palmer type - runge device Focal length of grating: 750mm Wavelength range: 130-650nm Open spark desk All kinds of fixture for special applications A cyclic flow saves the argon gas design Can quick swab incident window and replace Gap analysis: 4 mm Excitation Light Source: Programmable pulse digital light source Discharge frequency: Hz High-energy pre-combustion technology Ignition pulse amplitude: +15KV Peak pressure of main loop: 400VDC Working Environment and Power Supply: Power supply: 220V±10% , 50.

Hz±2% Max power: 1000W, standby 200W Working temperature: 10-30 ºC Relative humidity: 20-80%RH Requirement of Argon Gas: Purity>99.996% Size and Weight: Inlet pressure: 0.5MPa Size: L112×W75×H92cm Weight: 266 kg / 586 lb Excitation flow: 3L/min Factory/Workship/Certificates/Exhibition/Customer's Visit and Site Abroad installation

Optical | Applications and Buyer Notes

Optical is organized as a sourcing-ready Laboratory Instruments reference. The page combines visible product or company data with structured procurement cues so buyers can compare application fit, specifications, quantity, quality requirements and lead-time qu

Applications

  • Initial shortlist building for related product or supplier options.
  • Specification and application fit review before bulk purchasing.
  • Category, keyword and detail-page comparison before sending an RFQ.

Key specifications

Category
Laboratory InstrumentsBased on visible page data; confirm exact value in the RFQ.
Unit
setBased on visible page data; confirm exact value in the RFQ.
Size
and Weight: Inlet pressure: 0.5MPaBased on visible page data; confirm exact value in the RFQ.
type
runge device Focal length of grating: 750mm Wavelength range: 130-650nm Open spaBased on visible page data; confirm exact value in the RFQ.
Power
supply: 220V±10% , 50Hz±2% MaxBased on visible page data; confirm exact value in the RFQ.
Origin
WuxiBased on visible page data; confirm exact value in the RFQ.
Warranty
1 YearBased on visible page data; confirm exact value in the RFQ.
Advantage
High SensitiveBased on visible page data; confirm exact value in the RFQ.

Buyer tips

  • State quantity range and split-delivery needs before price comparison.
  • Add certification, material or inspection standards when they affect acceptance.
  • For time-sensitive projects, include target arrival date and destination.
  • For special applications, describe operating condition, installation environment and duty cycle.

FAQ

What should buyers confirm first?

Confirm application, specification, quantity, destination and lead-time requirements before comparing offers.

Can buyers inquire when specs are incomplete?

Yes. Add model, material, size, use case and inspection needs in the RFQ to make replies comparable.

How should this listing be evaluated?

Check title, category, specifications and related keywords against the actual sourcing requirement.

Source mix: ugc

Key specifications

CategoryLaboratory Instruments
Unitset
Sizeand Weight: Inlet pressure: 0.5MPa
typerunge device Focal length of grating: 750mm Wavelength range: 130-650nm Open spark desk All kinds of fixture for special
Powersupply: 220V±10% , 50Hz±2% Max
OriginWuxi
Warranty1 Year
AdvantageHigh Sensitive
Model NO.JB-750
PrincipleClassic Spectrometer
TrademarkJB
frequencyHz High-energy pre-combustion technology Ignition pulse amplitude: +15KV Peak pressure of main loop: 400VDC Working Environment and
CustomizedCustomized
ApplicationIndustrial
WavelengthsUV Spectrometer
Light NumberMonochromator
CertificationRoHS, ISO9001, CE
CustomizationAvailable
Delivery Time14days
SpecificationCE/RoHS/ISO/WSC
Optical SystemExcitation Desk:
Purity>99.996%Size and Weight:
Detection MethodSpectrophotometer
Transport PackageWooden Case/Carton/Pallet(Depends on)
Dispersive ElementInterferometer Spectrometer
Production Capacity20sets/Month
Inlet pressure: 0.5MPaSize: L112×W75×H92cm Weight: 266 kg / 586 lb
US$15, ,000.001 Set ( )

Product sourcing keywords

These terms come from the title, visible copy and specifications, and link into matching aggregate pages.

Continue from this detail page into sourcing structure

These links connect the detail page back to category hubs, procurement aggregates and knowledge pages so new inventory is not isolated.

LabInstSource related sourcing paths

Related applications LabInstSource related paths

Quality Control Labs

Materials and Industrial Analysis

Pharma and Biotech Testing

Related solutions LabInstSource related paths

High Precision Lab Setup

Cleanroom Monitoring and Supplies

LabInstSource procurement phrases

LabInstSource related product samples