LabInstSourceLab instruments, testing equipment, balances, microscopes, cleanroom products, and technical sourcing support for global buyers.
Laboratory Stability Xenon Lamp Aging Test Chamber
Laboratory Instruments

Laboratory Stability Xenon Lamp Aging Test Chambe | RFQ Sourcing Details

Laboratory Instruments · Quote on request

This is a product procurement detail page: check specs, images, category context and related sourcing paths before sending an RFQ.

Quote on request

Product specs

CategoryLaboratory Instruments
Unitset
SizeW*H*D) 180*190*130cm Temperature Range Rt~70 Degrees Temperature Fluctuation +/-2 Degrees Inner Chamber
typethermal shock chamber View all High temperature oven series
ModelYXEL-216 YXEL-343 YXEL-512 YXEL-1000
Powersupply (V) AC 3ψ380V 60/50Hz
OriginGuangdong, China
Standarddevice Lamp 1pcs,guaze 1pcs Test
CategoryLaboratory Instruments
AvailabilityInquiry required
Updated2026-05-31

Buyer's Digest

Use this page as a product-first sourcing checkpoint before sending an RFQ. Category: Laboratory Instruments. Confirm application fit, capacity, materials, destination, lead time and compliance requirements before comparing suppliers.

Original product description

. . Model NO.

YXEL-512 Inner Chamber Size(W*H*D) 80*80*80cm External Chamber Size (W*H*D) 180*190*130cm Temperature Range Rt~70 Degrees Temperature Fluctuation +/-2 Degrees Inner Chamber Material SUS# Stainless Steel Plate External Chamber Material Steel Plate+Powder Coating Humidity Range 80%Rh~98%Rh, 30%Rh~98%Rh Power Supply 3 Phase AC 380V 50.

Hz Rain Cycle 0~99h Adjustable Sample Holder Rotating Speed 1~5 R/Min Transport Package Strong Wooden Case Specification CE, ISO, SGS Certification, etc Trademark Yuanyao Origin Guangdong, China HS Code Production Capacity 50sets/Month Laboratory Stability Xenon Lamp Aging Test Chamber Application: Laboratory Stability Xenon Lamp Aging Test Chamber is uses Xenon arc lamps that simulate the full sunlight spectrum to reproduce destructive light waves in different environments, providing enviromental simulation and accelerated testing for scientific research, product development and quality control.

Applied to control the product quality, such as in textiles, dyes, automotive interior parts, electronic, plastic products, electrical appliances, instruments, food, vehicles, metals, chemicals, building materials, aerospace, medical care and so on.

Specification: Model YXEL-216 YXEL-343 YXEL-512 YXEL-1000 Inside dimensions W×H×D ( cm ) 60×60×60 70×70×70 80×80×80 100×100×100 Outside dimensions W×H×D(cm) 120×170×110 130×180×120 140×190×130 150×200×140 Temperature range RT ~ 70 ºC Temperature fluctuation ±2 ºC Humidity range 80 ~ 98%RH , 30 ~ 98%RH Rain duration 0 ~ 99.99H(adjustable) Rain cycle 0 ~ 99H(adjustable) Wave length 290 ~ 800nm Radiation intensity 1000w/m 2±200 Radiometer Standard configuration Distance between sample holder and lamp 300 ~ 375mm Sample holder Rotating speed 1 ~ 5r/min External chamber material Steel plate with powder coating Inner chamber material SUS#304 stainless steel plate Cycling system Single cycle,centrifugal fan,split air duct structure Control system Touch screen programmable controller Protection device Overpressure,leakage,phase loss,over temperature,water shortage Power supply (V) AC 3ψ380V 60/50.

Hz Standard device Lamp 1pcs,guaze 1pcs Test standard GB/T , GB Customization service Non-standard or special requirements are all welcome Control system: 1. High precision temperature control instrument. 2. Programmable time controller (set test time, illumination time, condensation time, spraying time) 3.

Electronic components: Adopt product of national joint venture company. 4. Main configuraton: Temperature controller , time controller, illumination time accumulator, digital displayed ampere meter, inflow magnetic valve, UV lamp. Structure and material: 1.

Working room, smaple shelf, liner and shell are made from SUS#304, automatic control for inflow. 2. Stainless steel heater is equipped with water-break protection device.

It can automatically cut off the power in the humidifying system in the case of water shortage, the finned air heating tube is made of stainless steel materials, the over temperature protection device is installed in the vabinet, can effectively guarrantee test.

Laboratory | Applications and Buyer Notes

Laboratory is organized as a sourcing-ready Laboratory Instruments reference. The page combines visible product or company data with structured procurement cues so buyers can compare application fit, specifications, quantity, quality requirements and lead-time

Applications

  • Initial shortlist building for related product or supplier options.
  • Specification and application fit review before bulk purchasing.
  • Category, keyword and detail-page comparison before sending an RFQ.

Key specifications

Category
Laboratory InstrumentsBased on visible page data; confirm exact value in the RFQ.
Unit
setBased on visible page data; confirm exact value in the RFQ.
Size
W*H*D) 180*190*130cm Temperature Range Rt~70 Degrees Temperature Fluctuation +/-Based on visible page data; confirm exact value in the RFQ.
type
thermal shock chamber View all High temperature oven seriesBased on visible page data; confirm exact value in the RFQ.
Model
YXEL-216 YXEL-343 YXEL-512 YXEL-1000Based on visible page data; confirm exact value in the RFQ.
Power
supply (V) AC 3ψ380V 60/50HzBased on visible page data; confirm exact value in the RFQ.
Origin
Guangdong, ChinaBased on visible page data; confirm exact value in the RFQ.
Standard
device Lamp 1pcs,guaze 1pcs TestBased on visible page data; confirm exact value in the RFQ.

Buyer tips

  • State quantity range and split-delivery needs before price comparison.
  • Add certification, material or inspection standards when they affect acceptance.
  • For time-sensitive projects, include target arrival date and destination.
  • For special applications, describe operating condition, installation environment and duty cycle.

FAQ

What should buyers confirm first?

Confirm application, specification, quantity, destination and lead-time requirements before comparing offers.

Can buyers inquire when specs are incomplete?

Yes. Add model, material, size, use case and inspection needs in the RFQ to make replies comparable.

How should this listing be evaluated?

Check title, category, specifications and related keywords against the actual sourcing requirement.

Source mix: ugc

Key specifications

CategoryLaboratory Instruments
Unitset
SizeW*H*D) 180*190*130cm Temperature Range Rt~70 Degrees Temperature Fluctuation +/-2 Degrees Inner Chamber
typethermal shock chamber View all High temperature oven series
ModelYXEL-216 YXEL-343 YXEL-512 YXEL-1000
Powersupply (V) AC 3ψ380V 60/50Hz
OriginGuangdong, China
Standarddevice Lamp 1pcs,guaze 1pcs Test
Warranty1 Year
Model NO.YXEL-512
TrademarkYuanyao
frequencyvibration tester Transportation vibration test machine Drop tester High
Rain Cycle0~99h Adjustable
Rain cycle0 ~ 99H(adjustable)
Wave length290 ~ 800nm
Power Supply3 Phase AC 380V 50Hz
CertificationCE, TUV, ISO, SGS
CustomizationAvailable
Rain duration0 ~ 99.99H(adjustable)
SpecificationCE, ISO, SGS Certification, etc
Test standardGB/T , GB
Cycling systemSingle cycle,centrifugal fan,split air duct structure
Humidity Range80%Rh~98%Rh, 30%Rh~98%Rh
Humidity range80 ~ 98%RH , 30 ~ 98%RH
Standard deviceLamp 1pcs,guaze 1pcs
Power supply (V)AC 3ψ380V 60/50Hz
Protection deviceOverpressure,leakage,phase loss,over temperature,water shortage
Temperature RangeRt~70 Degrees
Temperature rangeRT ~ 70 ºC
Transport PackageStrong Wooden Case
Production Capacity50sets/Month
Radiation intensity1000w/m 2±200
Customization serviceNon-standard or special requirements are all welcome
US$4, ,000.001 Piece ( )
Inner Chamber MaterialSUS# Stainless Steel Plate
Inner chamber materialSUS#304 stainless steel plate
Temperature Fluctuation+/-2 Degrees
Temperature fluctuation±2 ºC
Inner Chamber Size(W*H*D)80*80*80cm
Sample Holder Rotating Speed1~5 R/Min
Sample holder Rotating speed1 ~ 5r/min
External Chamber Size (W*H*D)180*190*130cm
Outside dimensions W×H×D(cm)120×170×110 130×180×120 140×190×130 150×200×140
Inside dimensions W×H×D ( cm )60×60×60 70×70×70 80×80×80 100×100×100
Distance between sample holder and lamp300 ~ 375mm

Product sourcing keywords

These terms come from the title, visible copy and specifications, and link into matching aggregate pages.