LabInstSourceLab instruments, testing equipment, balances, microscopes, cleanroom products, and technical sourcing support for global buyers.
XT-48BN Digital Whiteness and Brightness Meter for Paper, Paperboard, Pulp and Powder Samples
Laboratory Instruments

XT-48BN Digital Whiteness and Brightness Meter fo | RFQ Sourcing Details

Laboratory Instruments · Quote on request

This is a product procurement detail page: check specs, images, category context and related sourcing paths before sending an RFQ.

Quote on request

Product specs

CategoryLaboratory Instruments
Unitset
ModelXT-48BN
PrinterBuilt-in thermal printer
Net weight12 kg
Rated power50 W
Power supplyAC 100–240 V, 50/60 Hz
Instrument typeDigital whiteness and brightness meter
CategoryLaboratory Instruments
AvailabilityInquiry required
Source date2026-07-23

Buyer's Digest

Use this page as a product-first sourcing checkpoint before sending an RFQ. Category: Laboratory Instruments. Confirm application fit, capacity, materials, destination, lead time and compliance requirements before comparing suppliers.

Original product description

The XT-48BN is a digital laboratory whiteness and brightness meter intended for production control and commodity inspection where the optical properties of white or light-colored materials must be evaluated.

Its stated sample range includes paper, paperboard, pulp, plastic, salt, industrial salt, starch, calcium carbonate, talcum powder and other powders. The test plate diameter must be at least 30 mm.

Supported measurement functions include D65 brightness, identified as R457 blue-light whiteness;evaluation of fluorescent whitening caused by fluorescent substances in samples containing fluorescent whitening agents;and the Y10 brightness stimulus value, described as the green diffuse reflection factor Ry.

The listed functions also include light-scattering coefficient S, light-absorption coefficient A and ink absorption value. Opacity OP and transparency are identified as customized functions, while optical-density or pencil-lead concentration measurement requires a customized small-aperture configuration.

The instrument uses a digital display and computer control. It has a built-in thermal printer and an RS232 communication interface. Communication with PC software is listed as optional. A power-off protection function retains calibration data after the instrument is switched off.

The power supply accepts AC 100–240 V at 50/60 Hz, with rated power of 50 W. The instrument measures 380 × 260 × 400 mm and has a net weight of 12 kg. A flattening powder holder and fiber sample holder are listed as standard accessories.

The product information references GB/T 7973, GB/T 7974, GB/T 2679, GB/T 1543, GB/T 10339, GB/T 12911, GB/T 2913, GB/T 13025.2, GB/T 22427.6, ISO 2469, ISO 2470, ISO 2471 and ISO 9416.

Before procurement, buyers should confirm which measurement functions are enabled in the offered configuration, especially opacity, transparency and small-aperture optical-density testing.

Also confirm whether PC software is included, the exact reporting outputs, calibration and reference-standard provisions, sample-holder suitability for the intended material, and the specific clauses or methods supported under each listed standard.

These configuration questions should be resolved against the buyer’s sample type and laboratory procedure before ordering.

XT-48BN | Applications and Buyer Notes

XT-48BN is organized as a sourcing-ready Laboratory Instruments reference. The page combines visible product or company data with structured procurement cues so buyers can compare application fit, specifications, quantity, quality requirements and lead-time qu

Applications

  • Initial shortlist building for related product or supplier options.
  • Specification and application fit review before bulk purchasing.
  • Category, keyword and detail-page comparison before sending an RFQ.

Key specifications

Category
Laboratory InstrumentsBased on visible page data; confirm exact value in the RFQ.
Unit
setBased on visible page data; confirm exact value in the RFQ.
Model
XT-48BNBased on visible page data; confirm exact value in the RFQ.
Printer
Built-in thermal printerBased on visible page data; confirm exact value in the RFQ.
Net weight
12 kgBased on visible page data; confirm exact value in the RFQ.
Rated power
50 WBased on visible page data; confirm exact value in the RFQ.
Power supply
AC 100–240 V, 50/60 HzBased on visible page data; confirm exact value in the RFQ.
Instrument type
Digital whiteness and brightness meterBased on visible page data; confirm exact value in the RFQ.

Buyer tips

  • State quantity range and split-delivery needs before price comparison.
  • Add certification, material or inspection standards when they affect acceptance.
  • For time-sensitive projects, include target arrival date and destination.
  • For special applications, describe operating condition, installation environment and duty cycle.

FAQ

What should buyers confirm first?

Confirm application, specification, quantity, destination and lead-time requirements before comparing offers.

Can buyers inquire when specs are incomplete?

Yes. Add model, material, size, use case and inspection needs in the RFQ to make replies comparable.

How should this listing be evaluated?

Check title, category, specifications and related keywords against the actual sourcing requirement.

Source mix: ugc

Key specifications

CategoryLaboratory Instruments
Unitset
ModelXT-48BN
PrinterBuilt-in thermal printer
Net weight12 kg
Rated power50 W
Power supplyAC 100–240 V, 50/60 Hz
Instrument typeDigital whiteness and brightness meter
Core measurementsD65 brightness-light whiteness), fluorescent whitening evaluation and Y10 brightness stimulus value
Referenced standardsGB/T 7973, GB/T 7974, GB/T 2679, GB/T 1543, GB/T 10339, GB/T 12911, GB/T 2913, GB/T 13025.2, GB/T 22427.6, ISO 2469, ISO 2470, ISO 2471 and ISO 9416
Instrument dimensions380 × 260 × 400 mm
Supported sample typesPaper, paperboard, pulp, plastic, salt, industrial salt, starch, calcium carbonate, talcum powder and other powders
Minimum test plate diameter30 mm
Standard accessories listedFlattening powder holder and fiber sample holder

Product sourcing keywords

These terms come from the title, visible copy and specifications, and link into matching aggregate pages.

Continue from this detail page into sourcing structure

These links connect the detail page back to category hubs, procurement aggregates and knowledge pages so new inventory is not isolated.

LabInstSource related sourcing paths

LabInstSource procurement phrases

LabInstSource related product samples

Supplier profile

LabInstSource Imported Supplier Pool
主营:Laboratory Instruments

View full profile >