LabInstSourceLab instruments, testing equipment, balances, microscopes, cleanroom products, and technical sourcing support for global buyers.
Portable 20kv Megger Meter
Hardness Testers

Portable 20kv Megger Meter | RFQ Sourcing Details

Hardness Testers · Quote on request

This is a product procurement detail page: check specs, images, category context and related sourcing paths before sending an RFQ.

Quote on request

Product specs

CategoryHardness Testers
Unitset
CategoryHardness Testers
AvailabilityInquiry required
Updated2026-05-26

Buyer's Digest

Use this page as a product-first sourcing checkpoint before sending an RFQ. Category: Hardness Testers. Confirm application fit, capacity, materials, destination, lead time and compliance requirements before comparing suppliers.

Original product description

General Information: EPR50X In as 7 ranges: 500V, 1000V, 2500V, 5000V, 10000V, 15000V, 20000V, the maximum test can reach 20TΩ, and the manual voltage regulation function.

Features: Designed in strict accordance with safety standards Insulation resistance range 20T Ω @20kV The short-circuit current can be adjusted, up to 5mA (up to 10mA short-circuit current products can be customized).

Automatically display the test values of polarization index (PI) and dielectric absorption ratio (DAR), which can test leakage current and capacitance. Excellent anti-interference performance, when the interference current reaches 2mA, the instrument still guarantees the test accuracy.

The capacitive test product discharges quickly. When the cable is tested, no manual discharge is required, and the instrument automatically discharges quickly. 2 power supply methods: use lithium-ion battery to supply power, and the battery life can reach 4 hours (when 20000V is empty).

At the same time, it can be charged in use. When the power fails, it can automatically switch from AC power supply to battery power supply. All English display, English prompt operation, simple and clear, and can display the insulation resistance simulation column.

Digital filter function, use the filter function to reduce the influence whenever the display value deviation caused by external influence. Complete protection function, and equipped with fuse blowing prompt function.

Measuring Range and Accuracy: Safety specifications IEC 61010-1 CAT.IV 600V Pollution degree 2 IEC 61326 EMC specification: electrical equipment for testing, control and inspection IEC60529 IP64 (outer box closed state) AC power supply: 220V±10%, 50/60 HZ, 20 VA Test voltage accuracy: 100% to 110% of the nominal value Voltage measurement accuracy: 5%+10V Current test range: 10mA Current measurement accuracy: 5%+0.2nA Short-circuit current: 2 to 5mA, adjustable output (10mA short-circuit current can be customized) Capacitance test range: 20uF Capacitance test accuracy: 15%+0.03uF Insulation resistance test range and accuracy temperature: 23±5ºC, relative temperature: 45 - 75%RH Dimensions (length x width x height): 37cm x 27cm x 17cm Weight: 3.5kg Range 500V 1000V 2500V 5000V 10000V 15000V 20000V Manual Control

Portable | Applications and Buyer Notes

Portable is organized as a sourcing-ready Hardness Testers reference. The page combines visible product or company data with structured procurement cues so buyers can compare application fit, specifications, quantity, quality requirements and lead-time questio

Applications

  • Initial shortlist building for related product or supplier options.
  • Specification and application fit review before bulk purchasing.
  • Category, keyword and detail-page comparison before sending an RFQ.

Key specifications

Category
Hardness TestersBased on visible page data; confirm exact value in the RFQ.
Unit
setBased on visible page data; confirm exact value in the RFQ.

Buyer tips

  • State quantity range and split-delivery needs before price comparison.
  • Add certification, material or inspection standards when they affect acceptance.
  • For time-sensitive projects, include target arrival date and destination.
  • For special applications, describe operating condition, installation environment and duty cycle.

FAQ

What should buyers confirm first?

Confirm application, specification, quantity, destination and lead-time requirements before comparing offers.

Can buyers inquire when specs are incomplete?

Yes. Add model, material, size, use case and inspection needs in the RFQ to make replies comparable.

How should this listing be evaluated?

Check title, category, specifications and related keywords against the actual sourcing requirement.

Source mix: ugc

Key specifications

CategoryHardness Testers
Unitset

Product sourcing keywords

These terms come from the title, visible copy and specifications, and link into matching aggregate pages.

Continue from this detail page into sourcing structure

These links connect the detail page back to category hubs, procurement aggregates and knowledge pages so new inventory is not isolated.

LabInstSource related sourcing paths

LabInstSource procurement phrases

LabInstSource related product samples