LabInstSourceLab instruments, testing equipment, balances, microscopes, cleanroom products, and technical sourcing support for global buyers.
Laboratory Modular Walk-in Temperature Humidity Climatic Test Chamber Walk-in Chamber
Laboratory Instruments

Laboratory Modular Walk-in Temperature Humidity C | RFQ Sourcing Details

Laboratory Instruments · Quote on request

This is a product procurement detail page: check specs, images, category context and related sourcing paths before sending an RFQ.

Quote on request

Product specs

CategoryLaboratory Instruments
Unitset
sizeand equipment are ideal for specific applications. Product Paramenters Operation
ColorCan Be Customized
InputTemp.:pt-100, Humidity:pt-100 or ~5V DCV
PowerSupply AC 3 Phase 380V 60/50Hz
OriginGuangdong, China (Mainland)
Volume7-150m3
CategoryLaboratory Instruments
AvailabilityInquiry required
Updated2026-05-30

Buyer's Digest

Use this page as a product-first sourcing checkpoint before sending an RFQ. Category: Laboratory Instruments. Confirm application fit, capacity, materials, destination, lead time and compliance requirements before comparing suppliers.

Original product description

Walk in test chambers are used in electrical, electronics, aerospace, battery, and automotive fields. It can be used to test significant components and as a temperature or humidity chamber. This walk in chamber is specially developed for large specimens. The size and design are the most loads for the test specimens.

Modular construction and variability in size and equipment are ideal for specific applications.

Product Paramenters Operation model Program or fix point running 120 programs,1200steps, all repeat 999 cycles, part repeat 99 cycles Memory capacity Controller Accuracy Temp.:0.1% of F.S±1 digit Humidity:0.1% of F.S±1 digit Input Temp.:pt-100, Humidity:pt-100 or ~5V DCV Comm.

port RS-232 or USB (Software is an option) Temp. range Maximum:80 ºC,150 ºC;Minimum:-60 ºC,-50 ºC,-40 ºC,-30 ºC,-20 ºC,-10 ºC,0 ºC Humidity Range Temp. constancy Humidity constancy Temp. uniformity ±2.0 ºC Humidity uniformity ±5.0%R.H Ambient Temp. +5 ºC~+35 ºC Wiring method AC 380±10% 50.

Hz ,3 phase 4 wires +Ground Wires Heat time +20 ºC~+80 ºC,Within 60 min Pull down time +20 ºC~-55 ºC, -40 ºC,-20 ºC,-10 ºC,Within 120 or 90 or 60 min Note:1. We reserve the right to change specifications without prior notice 2.

Customized sizes and configurations are available Walk In Chamber Features 1.The walk in climatic chamber can realize temperature constant value control and program control. 2.The entire data recorder function (optional) is for recording and retrospect.

Protect/heater for short circuit protection, ensuring the stability of air volume and heating during the operation. 3.It has a USB connector WAN communication function. It makes communication equipment and software extensions to meet customers' needs.

4.The walk in thermal chamber adopts an internationally popular refrigeration control mode. It can automatically adjust the compressor refrigeration power of 0% ~ 100%. Compared with the traditional thermal equilibrium temperature control mode, the energy consumption is reduced by 30%.

5.Refrigeration and electric control are key to adopting an internationally famous brand. It makes the whole of the equipment have improved the quality and guarantee. 7.We can customize the dimensions, metrics and various optional features of walk in climate chamber for you.

Advantage Customer Support Services Ø 24 hours online Ø 35 years experiences Ø Sample chamber of each model Ø Best price, fast delivery Ø OEM,ODM Ø Oversea offices Ø Own import and export business license ØISO,CE,UL,ASTM,DIN,EN,GB,BS,JIS,ANSI,TAPPI,AATCC,IEC,VDE Ø Installation Ø Training (Training customer employees) Ø Calibration Ø Preventative maintenance Ø Replacement parts Ø Assistance via

Laboratory | Applications and Buyer Notes

Laboratory is organized as a sourcing-ready Laboratory Instruments reference. The page combines visible product or company data with structured procurement cues so buyers can compare application fit, specifications, quantity, quality requirements and lead-time

Applications

  • Initial shortlist building for related product or supplier options.
  • Specification and application fit review before bulk purchasing.
  • Category, keyword and detail-page comparison before sending an RFQ.

Key specifications

Category
Laboratory InstrumentsBased on visible page data; confirm exact value in the RFQ.
Unit
setBased on visible page data; confirm exact value in the RFQ.
size
and equipment are ideal for specific applications. Product Paramenters OperationBased on visible page data; confirm exact value in the RFQ.
Color
Can Be CustomizedBased on visible page data; confirm exact value in the RFQ.
Input
Temp.:pt-100, Humidity:pt-100 or ~5V DCVBased on visible page data; confirm exact value in the RFQ.
Power
Supply AC 3 Phase 380V 60/50HzBased on visible page data; confirm exact value in the RFQ.
Origin
Guangdong, China (Mainland)Based on visible page data; confirm exact value in the RFQ.
Volume
7-150m3Based on visible page data; confirm exact value in the RFQ.

Buyer tips

  • State quantity range and split-delivery needs before price comparison.
  • Add certification, material or inspection standards when they affect acceptance.
  • For time-sensitive projects, include target arrival date and destination.
  • For special applications, describe operating condition, installation environment and duty cycle.

FAQ

What should buyers confirm first?

Confirm application, specification, quantity, destination and lead-time requirements before comparing offers.

Can buyers inquire when specs are incomplete?

Yes. Add model, material, size, use case and inspection needs in the RFQ to make replies comparable.

How should this listing be evaluated?

Check title, category, specifications and related keywords against the actual sourcing requirement.

Source mix: ugc

Key specifications

CategoryLaboratory Instruments
Unitset
sizeand equipment are ideal for specific applications. Product Paramenters Operation
ColorCan Be Customized
InputTemp.:pt-100, Humidity:pt-100 or ~5V DCV
PowerSupply AC 3 Phase 380V 60/50Hz
OriginGuangdong, China (Mainland)
Volume7-150m3
QualityCertificated
StandardCE, IEC, Mil
Warranty1 Year
Heat time+20 ºC~+80 ºC,Within 60 min
Model NO.XB-OTS-10m2B
TrademarkOTS
Comm. portRS-232 or USB
ControllerProgrammable LCD Touch Screen
RefrigerantR23/R404A
Temp. rangeMaximum:80 ºC,150 ºC;Minimum:-60 ºC-50 ºC-40 ºC-30 ºC-20 ºC-10 ºC,0 ºC
Package Size352.00cm * 200.00cm * 232.00cm
Power SupplyAC 3 Phase 380V 60/50Hz
Ambient Temp.+5 ºC~+35 ºC
CertificationCE, ISO
CustomizationAvailable
SpecificationW3000*H2000*D2000mm(Can be customized)
Wiring methodAC 380±10% 50Hz ,3 phase 4 wires +Ground Wires
Humidity Range20%~98%Rh
Pull down time+20 ºC~-55 ºC-40 ºC-20 ºC-10 ºC,Within 120 or 90 or 60 min
Operation modelProgram or fix point running 120 programs,1200steps, all repeat 999 cycles, part repeat 99 cycles
Temp. uniformity±2.0 ºC
Temperature Range80 Degree~ +150 Degree
Transport PackageAssembled and Integrated on-Site
After-sales ServiceOnline Services and Localization Services
Humidity uniformity±5.0%R.H
Production Capacity118 Pieces/Month

Product sourcing keywords

These terms come from the title, visible copy and specifications, and link into matching aggregate pages.

Continue from this detail page into sourcing structure

These links connect the detail page back to category hubs, procurement aggregates and knowledge pages so new inventory is not isolated.

LabInstSource related sourcing paths

Related applications LabInstSource related paths

Quality Control Labs

Pharma and Biotech Testing

Materials and Industrial Analysis

Related solutions LabInstSource related paths

High Precision Lab Setup

Cleanroom Monitoring and Supplies

LabInstSource procurement phrases

LabInstSource related product samples