LabInstSourceLab instruments, testing equipment, balances, microscopes, cleanroom products, and technical sourcing support for global buyers.
KDFJ-IV SF6 Gas Analyzer for Dew Point, Purity and Decomposition Testing
Laboratory Instruments

KDFJ-IV SF6 Gas Analyzer for Dew Point, Purity an | RFQ Sourcing Details

Laboratory Instruments · Quote on request

This is a product procurement detail page: check specs, images, category context and related sourcing paths before sending an RFQ.

Quote on request

Product specs

CategoryLaboratory Instruments
Unitset
ModelKDFJ-IV
ControlManual
DisplayDigital
Power sourceAC 220 V
Dew-point range80°C to +20°C
Instrument typeElectric testing machine / SF6 gas analyzer
CategoryLaboratory Instruments
AvailabilityInquiry required
Source date2026-07-24

Buyer's Digest

Use this page as a product-first sourcing checkpoint before sending an RFQ. Category: Laboratory Instruments. Confirm application fit, capacity, materials, destination, lead time and compliance requirements before comparing suppliers.

Original product description

The KDFJ-IV is a comprehensive SF6 gas analyzer designed to combine several measurements in one portable, digitally displayed instrument.

It measures SF6 dew point, purity, and selected decomposition products, making it suitable for laboratory testing and field inspection where these parameters must be checked with a single unit. Supported measurement capabilities The dew-point measuring range is -80°C to +20°C, with stated accuracy of ±0.5°C.

When the dew-point temperature is below 0°C, the sensor output represents frost point. Stated response times are 5 seconds to reach 63% and 45 seconds to reach 90% when moving from -80°C to +20°C. In the reverse direction, from +20°C to -80°C, the stated response times are 10 seconds to 63% and 240 seconds to 90%.

For SF6 decomposition testing, the instrument provides an H2S range of 0–100 μL/L, an SO2 range of either 0–100 μL/L or 0–2000 μL/L, and a CO range of 0–1000 μL/L. For H2S and SO2 readings at or below 10 μL/L, the stated error is no more than ±0.2 μL/L;above 10 μL/L, it is no more than ±3%.

SF6 purity is measured over a 0–100% weight-ratio range. The stated purity accuracy is no more than ±0.2%, with a measurement time of under two minutes. The analyzer uses manual control, an AC 220 V power source, and a digital display.

Its stated instrument weight is 7.3 kg, and the listed specification is 300 × 350 × 100 mm.

Procurement questions to confirm Before ordering, buyers should confirm which SO2 range is supplied, the exact sensor configuration, included sampling components and accessories, power-cord and plug configuration, calibration documentation, and whether calibration is traceable to a required standard.

Also verify operating and storage conditions, gas-flow requirements, warm-up time, data storage or export functions, replacement-sensor availability, and the maintenance schedule.

Confirm whether the listed dimensions refer to the instrument itself and request the final packing list, because separate package dimensions and gross weight are stated.

If a warranty or customized configuration is required, obtain the applicable scope, exclusions, deliverables, and acceptance criteria in the purchase documentation.

KDFJ-IV | Applications and Buyer Notes

KDFJ-IV is organized as a sourcing-ready Laboratory Instruments reference. The page combines visible product or company data with structured procurement cues so buyers can compare application fit, specifications, quantity, quality requirements and lead-time qu

Applications

  • Initial shortlist building for related product or supplier options.
  • Specification and application fit review before bulk purchasing.
  • Category, keyword and detail-page comparison before sending an RFQ.

Key specifications

Category
Laboratory InstrumentsBased on visible page data; confirm exact value in the RFQ.
Unit
setBased on visible page data; confirm exact value in the RFQ.
Model
KDFJ-IVBased on visible page data; confirm exact value in the RFQ.
Control
ManualBased on visible page data; confirm exact value in the RFQ.
Display
DigitalBased on visible page data; confirm exact value in the RFQ.
Dew-point range
80°C to +20°CBased on visible page data; confirm exact value in the RFQ.
Instrument type
Electric testing machine / SF6 gas analyzerBased on visible page data; confirm exact value in the RFQ.

Buyer tips

  • State quantity range and split-delivery needs before price comparison.
  • Add certification, material or inspection standards when they affect acceptance.
  • For time-sensitive projects, include target arrival date and destination.
  • For special applications, describe operating condition, installation environment and duty cycle.

FAQ

What should buyers confirm first?

Confirm application, specification, quantity, destination and lead-time requirements before comparing offers.

Can buyers inquire when specs are incomplete?

Yes. Add model, material, size, use case and inspection needs in the RFQ to make replies comparable.

How should this listing be evaluated?

Check title, category, specifications and related keywords against the actual sourcing requirement.

Source mix: ugc

Key specifications

CategoryLaboratory Instruments
Unitset
ModelKDFJ-IV
ControlManual
DisplayDigital
Power sourceAC 220 V
Dew-point range80°C to +20°C
Instrument typeElectric testing machine / SF6 gas analyzer
SF6 purity range0–100% by weight ratio
Instrument weight7.3 kg
CO measuring range0–1000 μL/L
Dew-point accuracy±0.5°C
H2S measuring range0–100 μL/L
SO2 measuring range0–100 μL/L or 0–2000 μL/L
Listed specification300 × 350 × 100 mm
H2S and SO2 accuracy at >10 μL/LError ≤±3%
H2S and SO2 accuracy at ≤10 μL/LError ≤±0.2 μL/L
Dew-point response, +20°C to -80°C10 seconds to 63%;240 seconds to 90%
Dew-point response, -80°C to +20°C5 seconds to 63%;45 seconds to 90%

Product sourcing keywords

These terms come from the title, visible copy and specifications, and link into matching aggregate pages.

Continue from this detail page into sourcing structure

These links connect the detail page back to category hubs, procurement aggregates and knowledge pages so new inventory is not isolated.

LabInstSource related sourcing paths

LabInstSource procurement phrases

LabInstSource related product samples

Supplier profile

LabInstSource Imported Supplier Pool
主营:Laboratory Instruments

View full profile >