LabInstSourceLab instruments, testing equipment, balances, microscopes, cleanroom products, and technical sourcing support for global buyers.
Erun-Sp9-B6 High-Accuracy Turbidimeter Laboratory-Grade Tool for Industrial Water Quality Testing
Laboratory Instruments

Erun-Sp9-B6 High-Accuracy Turbidimeter Laboratory | RFQ Sourcing Details

Laboratory Instruments · Quote on request

This is a product procurement detail page: check specs, images, category context and related sourcing paths before sending an RFQ.

Quote on request

Product specs

CategoryLaboratory Instruments
Unitset
No.Measurement item Measuring range Unit Indication error
TypeTurbidity Meter
Power36W
colortouch screen, featuring a user-friendly operation
OriginChina
Weight9.1kg
CategoryLaboratory Instruments
AvailabilityInquiry required
Updated2026-05-31

Buyer's Digest

Use this page as a product-first sourcing checkpoint before sending an RFQ. Category: Laboratory Instruments. Confirm application fit, capacity, materials, destination, lead time and compliance requirements before comparing suppliers.

Original product description

. Overview Technical Parameters Measurable item Overview . Model NO. SP9-B6 Display LCD Appliance Biochemistry, Laboratory Portable Portable Certification ISO9001 Type Turbidity Meter Weight 9.1kg Power 36W Parameters Turbidity Model No.

Erun-Sp9-B6 Transport Package Carton Specification 455mm*333mm*140mm Trademark EURN Origin China HS Code Introduction This instrument features 16 channels for the optical method and can measure over 60 parameters, as well as PH, conductivity, TDS, salinity, dissolved oxygen and water temperature by the electrode method.

Users can freely combine as needed. The instrument is equipped with a dual-temperature-controlled digestion device and contains a large-capacity lithium battery, which can be used for water quality testing in on-site environments without power supply.

The products are widely applicable to fields such as scientific research, universities, sewage treatment, water environment testing, self-inspection of enterprise sewage, drinking water, surface water and groundwater testing. Product Features 1.

It can detect the concentration, absorbance and transmittance of nearly a hundred parameters in water quality, and can store, print, query and upload the concentration values to the computer. 2.

The instrument is equipped with an 8-hole dual-temperature zone digestion device, featuring a 4+4 dual-temperature zone design with independent temperature control, making it suitable for multi-index and batch project testing. 3.

The electrode method and spectrophotometry are integrated into one, meeting the multi-item: parameter testing requirements of electrochemical method and colorimetric method. 4. Three-proof chassis: Dust-proof, water-proof, and shock-proof. Integrated equipment, covering all the needs of outdoor water quality testing.

Easy to use and portable. 5. Outdoor detection eliminates battery life anxiety. Continuous dual-temperature digestion can last up to 3 hours, supports simultaneous digestion of multiple parameters, and the main unit's battery life can reach 48 hours. 6.

It can store 200 factory curves, add 3,000 user curves, and store up to 99,999 records. 7. The LED light source responds quickly, the instrument can be used immedia ry curve and user curve data records are lost due to an accident, one-click recovery can be achieved. 9.

The instrument can take backup measures for the curves and data records calibrated by the user. In case of unexpected loss, recovery operations can be carried out. 10.

The instrument is equipped with a large-screen color touch screen, featuring a user-friendly operation interface and an operation guide that explains the operation of various functions. 11. Personalized and free customization.

Detection parameters and measurement ranges can be customized and upgraded according to requirements. 12. The instrument is equipped with various security measures. It can be set to enter passwords for startup and system Settings to prevent other personnel from making incorrect operations on the instrument Settings.

13. The light intensity is adjustable, divided into 16 levels, and can be set arbitrarily, which can effectively solve the problem of measurement range expansion caused by the strength of the signal. 14.

Support optical calibration to ensure the accuracy of optical components, enhance the precision, stability and service life of the instrument;15. It can store up to 100,000 records (including parameter names, concentrations, units, detection times, operator numbers, etc.).

When querying records, single-item printing or page printing can be performed. 16. Curve query is possible.

Besides querying the curve equation, the standard value of each standard substance during calibration, the corresponding absorbance, the calibration time and the calibration personnel number can also be queried, fully reproducing the state at the time of calibration. 17.

The system has a bilingual function and can switch between Chinese and English. 18. It has a USB port and can transfer data to a computer.

Technical Parameters Technical Parameters Measurement parameters Turbidity Wavelength 340nm,420nm,440nm,470nm,520nm,540nm,560nm,610nm,630nm,660nm,680nm, 700nm Any wavelength within the above range can be customized, and the instrument will automatically select the wavelength Indication error ≤±5 % Repeatability ≤2% Optical stability The absorbance value drifts less than 0.002A within 20 minutes (100,000-hour lifespan) Dimension 455mm*333mm*140mm Power 36W Weight 9.1kg Working environment (1)Ambient temperature :5-40ºC \ n;(2) Relative humidity: ≤85% \ n;(3) Power supply: Lithium battery/AC (220±22)V (50±0.5) Hz;(4) There should be no significant vibration or electromag Measurable item Measurement items No.

Erun-Sp9-B6 | Applications and Buyer Notes

Erun-Sp9-B6 is organized as a sourcing-ready Laboratory Instruments reference. The page combines visible product or company data with structured procurement cues so buyers can compare application fit, specifications, quantity, quality requirements and lead-tim

Applications

  • Initial shortlist building for related product or supplier options.
  • Specification and application fit review before bulk purchasing.
  • Category, keyword and detail-page comparison before sending an RFQ.

Key specifications

Category
Laboratory InstrumentsBased on visible page data; confirm exact value in the RFQ.
Unit
setBased on visible page data; confirm exact value in the RFQ.
No.
Measurement item Measuring range Unit Indication errorBased on visible page data; confirm exact value in the RFQ.
Type
Turbidity MeterBased on visible page data; confirm exact value in the RFQ.
Power
36WBased on visible page data; confirm exact value in the RFQ.
color
touch screen, featuring a user-friendly operationBased on visible page data; confirm exact value in the RFQ.
Origin
ChinaBased on visible page data; confirm exact value in the RFQ.
Weight
9.1kgBased on visible page data; confirm exact value in the RFQ.

Buyer tips

  • State quantity range and split-delivery needs before price comparison.
  • Add certification, material or inspection standards when they affect acceptance.
  • For time-sensitive projects, include target arrival date and destination.
  • For special applications, describe operating condition, installation environment and duty cycle.

FAQ

What should buyers confirm first?

Confirm application, specification, quantity, destination and lead-time requirements before comparing offers.

Can buyers inquire when specs are incomplete?

Yes. Add model, material, size, use case and inspection needs in the RFQ to make replies comparable.

How should this listing be evaluated?

Check title, category, specifications and related keywords against the actual sourcing requirement.

Source mix: ugc

Key specifications

CategoryLaboratory Instruments
Unitset
No.Measurement item Measuring range Unit Indication error
TypeTurbidity Meter
Power36W
colortouch screen, featuring a user-friendly operation
OriginChina
Weight9.1kg
DisplayLCD
PortablePortable
Warranty1 Year
standardvalue of each
ApplianceBiochemistry, Laboratory
Dimension455mm*333mm*140mm
Model NO.SP9-B6
Model No.Erun-Sp9-B6
TrademarkEURN
ParametersTurbidity
Wavelength340nm,420nm,440nm,470nm,520nm,540nm,560nm,610nm,630nm,660nm,680nm, 700nm Any wavelength within the above range can be customized, and the instrument will automatically select the wavelength
US$1,298.001 Piece ( )
CertificationISO9001
CustomizationAvailable
Specification455mm*333mm*140mm
Optical stabilityThe absorbance value drifts less than 0.002A within 20 minutes-hour lifespan
Transport PackageCarton
After-sales ServiceProvide Timely and Accurate Online After-Sales Ser
Working environment1)Ambient temperature :5-40ºC \ n
Measurement parametersTurbidity

Product sourcing keywords

These terms come from the title, visible copy and specifications, and link into matching aggregate pages.

Continue from this detail page into sourcing structure

These links connect the detail page back to category hubs, procurement aggregates and knowledge pages so new inventory is not isolated.

LabInstSource related sourcing paths

LabInstSource procurement phrases

LabInstSource related product samples