
Biological Oxygen Demand Analyzer Lab BOD Analyze | RFQ Sourcing Details
Laboratory Instruments · Quote on request
This is a product procurement detail page: check specs, images, category context and related sourcing paths before sending an RFQ.
Quote on requestProduct specs
Buyer's Digest
Use this page as a product-first sourcing checkpoint before sending an RFQ. Category: Laboratory Instruments. Confirm application fit, capacity, materials, destination, lead time and compliance requirements before comparing suppliers.
Original product description
Overview The MDS-B3 BOD analyzer is designed based on the differential pressure method. It simulates the biodegradation process of organic matter in nature within a sealed culture flask.
Oxygen from the air above the flask continuously replenishes the dissolved oxygen consumed by the decomposition of organic matter in the sample. The CO2 produced during the degradation process is removed, causing a change in air pressure within the culture flask.
By monitoring this change in air pressure, the BOD value of the sample is calculated. Basic features 1. High-sensitivity dissolving gas sensor, guaranteed number of installations 2. Support automatic sizing, constant temperature cultivation, numerical installation, and analysis 3. Available at a small time BOD 4.
LCD, tactile operation, number of functions 5. Complete international/national standard Precautions 1. Before using the instrument, please carefully read the "Safety Warnings and Precautions" in the instruction manual to ensure correct and safe use. 2.
Adhering to the usage principles can extend the product's lifespan and prevent potential hazards. 3. This product is intended for highly specialized industries. Personnel using and operating it must possess the relevant professional knowledge and skills.
Accuracy Meets the water quality 5-day BOD accuracy test standard (glucose-glutamic acid standard solution 5-day BOD = 180-230 mmg/L). Measuring Range 0-4000mg/L Measurement. Days 1-30 days Measurement Quantity ≤ 6 pieces Storage. Quantity 10 year BOD5 result values Volumeof Cultivation.
Bottle 580ml Incubation Temperature 20±1ºC Power Supply DC15V/2A Rated. Power 15W Size 292mm×200mm×81.5mm Weight 2.5kg Application Screnario Main Products
Biological | Applications and Buyer Notes
Biological is organized as a sourcing-ready Laboratory Instruments reference. The page combines visible product or company data with structured procurement cues so buyers can compare application fit, specifications, quantity, quality requirements and lead-time
Applications
- Initial shortlist building for related product or supplier options.
- Specification and application fit review before bulk purchasing.
- Category, keyword and detail-page comparison before sending an RFQ.
Key specifications
- Category
- Laboratory InstrumentsBased on visible page data; confirm exact value in the RFQ.
- Unit
- setBased on visible page data; confirm exact value in the RFQ.
- Size
- 292mm×200mm×81.5mmBased on visible page data; confirm exact value in the RFQ.
- Type
- LABBased on visible page data; confirm exact value in the RFQ.
- Power
- Supply DC15V/2A RatedPower 15WBased on visible page data; confirm exact value in the RFQ.
- Origin
- ChinaBased on visible page data; confirm exact value in the RFQ.
- Weight
- 2.5kgBased on visible page data; confirm exact value in the RFQ.
- Display
- DigitalBased on visible page data; confirm exact value in the RFQ.
Buyer tips
- State quantity range and split-delivery needs before price comparison.
- Add certification, material or inspection standards when they affect acceptance.
- For time-sensitive projects, include target arrival date and destination.
- For special applications, describe operating condition, installation environment and duty cycle.
FAQ
What should buyers confirm first?
Confirm application, specification, quantity, destination and lead-time requirements before comparing offers.
Can buyers inquire when specs are incomplete?
Yes. Add model, material, size, use case and inspection needs in the RFQ to make replies comparable.
How should this listing be evaluated?
Check title, category, specifications and related keywords against the actual sourcing requirement.
Source mix: ugc
Key specifications
Product sourcing keywords
These terms come from the title, visible copy and specifications, and link into matching aggregate pages.
Continue from this detail page into sourcing structure
These links connect the detail page back to category hubs, procurement aggregates and knowledge pages so new inventory is not isolated.
This URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path Cleanroom And Lab Furniture categoryThis URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path Laboratory Instruments categoryThis URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path Sample Preparation And Consumables categoryThis URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path Testing And Measurement Equipment categoryThis URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path Procurement sourcing pathThis URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path 0 001g High Accuracy Laboratory Grade Analytical Balance For Gold Jewelry Measurement Analytical BThis URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path Cleanroom Monitoring Systems sourcing pathThis URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path Cleanroom Product Suppliers sourcing pathThis URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path Digital Inspection Microscopes sourcing pathThis URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path 16500rpm High Speed Capillary Hematocrit Centrifuge For Hospital Medical Use Hematocrit CentrifugeThis URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path Advanced Cup Temperature Shock Test Chamber For Gas ImpactThis URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path Aoda 2700 Nir Spectrometer For Food Feed And Grain AnalysisThis URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path CompanyThis URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
LabInstSource related sourcing paths
LabInstSource procurement phrases
LabInstSource related product samples
We are a manufacturer specializing in the R&D of laboratory electric heating equipment. Our process is unique worldwide,...
Sample Preparation and Lab Basics Semi-Exhaust Type Biological Safety Cabinet Machine Medical Equipment - Medical Equipment and MedicaSemi-exhaust type biological safety cabinet school laboratory 1.Description The biosafety cabinet protects both human sa...
Sample Preparation and Lab Basics Etcolabs PP Fume Hood - Compliant with En 14175 Ashrae mm - 2026 Fume Hood, En 14175 FuIn the domain of laboratory safety, our fume hoods stand as indispensable protectors, catering to the rigorous demands o...
Sample Preparation and Lab Basics Laboao InUsing American Marlow semiconductor refrigeration sheet, the maximum temperature change rate is more than 5 degrees per ...
Sample Preparation and Lab Basics Erun-Sp9-B6 High-Accuracy Turbidimeter Laboratory-Grade Tool for Industrial Water Quality TestingIntroduction This instrument features 16 channels for the optical method and can measure over 60 parameters, as well as ...
Sample Preparation and Lab Basics Cordial Lab 5-5000ml Borosilicate 3.3 Glass Low Form Beaker for Lab Use - Glass Beaker and Low Form: With Spout and graduations 4. Color: Clear-to-read white enamel graduated scale. 2) Borosilicate tubing made and machi...





