LabInstSourceLab instruments, testing equipment, microscopes, balances, and cleanroom supplies
Ultra-Low Frequency High-Voltage Generator for Electric Cable and Motor Insulation Test
Optical Instrument

Ultra-Low Frequency High-Voltage Generator for Electric Cable and Motor Insulation Test

Laboratory detail pages should help buyers judge whether one instrument or consumable fits the intended workflow, validation scope and environment before RFQ.

Quote on request

Product sourcing profile

CategoryOptical Instrument
Inquiry workflowPlatform RFQ workflow
AvailabilityInquiry required
Updated2026-05-05

Product introduction

Ultra-Low Frequency High-Voltage Generator for Electric Cable and Motor Insulation Test US$800.00-5,000.00 1 Piece-sales Service: Life Time Warranty: 1 Year MaLabInstSource curates RFQ-led product discovery for buyers looking for microscopes options. The page is organized around specification review, application fit, and inquiry-ready comparison.When evaluating this product, buyers should confirm application fit, required performance range, installation environment, lead time, documentation, and whether the supplier can support OEM or project quotations. Current vertical focus: laboratory instrument sourcing, testing equipment discovery, and rfq-ready lab supply platform.

Selection and RFQ points

Review material fit, application context, alternatives and RFQ detail before comparing related product paths.

Material fit Frequency High-voltage Generator Electric Cable

Confirm material, size, finish, tolerance and processing needs before price comparison.

Application fit application, operating environment and usage frequency

Add the target application and operating context so related products can be compared correctly.

Alternative path Motor

Use nearby materials, equipment types or category pages when this record is close but not exact.

RFQ detail Quantity, destination, timing

Include quantity, destination, target delivery window, packaging and any technical constraints.

LabInstSource quality checks

Workflow contextConfirm whether the item fits the intended lab, QC or cleanroom workflow.

Use this check before moving from discovery into product comparison or RFQ submission.

Validation requirementCheck sample type, accuracy, environment and certification needs before comparing offers.

Use this check before moving from discovery into product comparison or RFQ submission.

Procurement detailBring validation scope, operating environment and documentation requirements into the RFQ.

Use this check before moving from discovery into product comparison or RFQ submission.

Key specifications

CategoryMicroscopes
Brand
Unitset
30KV30kV/20mA (peak value) 0.1Hz,≤0.5µF~1.1µF 5A Controller:4kg Booster:25kg
50KV50kV/30mA (peak value) 0.1Hz,≤0.5µF~1.1µF 7A Controller:4kg Booster:50kg
60KV60kV/30mA (peak value) 0.1Hz,≤0.5µF 9A Controller:4kg Booster1(30kV):25kg Booster2(30kV):25kg
80KV80kV/30mA (peak value) 0.1Hz,≤0.5µF 12A Controller:4kg Booster1(30kV):25kg Booster2(50kV):50kg
Accuracy Grade0.5
After-sales ServiceLife Time
ApplicationIndustrial automation and process control
Capacity100kg
CategoryMicroscopes
ControlComputer Control
CustomizationAvailable
DisplayDigital
Environment Temperature10℃~+40℃
Feature Highlightsdigital, automatic
Humidity≤85%Rh
LanguageEnglish
Measurement Accuracy1%
ModelRelated voltage On-load capacity Power source protective-tube Weight
Model NO.CYVLF-30
OriginWuhan, China
Output Frequency0.1Hz, 0.05Hz, 0.02Hz
Output Rated Voltage30kv-80kv
Power SourceAC220V
Product TitleUltra-Low Frequency High-Voltage Generator for Electric Cable and Motor Insulation Test
SpecificationISO 19001, ISO 14001, OHSAS 18001
TrademarkKIYU
US$800.00-5,000.001 Piece (MOQ)
Voltage30kv
Voltage Plus&Minus Peak Value Error≤3%
Voltage Waveform Distortion≤5%
Warranty1 Year
Weight0-100Kg

Keyword evidence

Only terms with visible evidence in this listing are shown here.

Product sourcing keywords

These terms come from the title, visible copy and specifications, and link into matching aggregate pages.

Related keyword paths

Grouped by the product keyword that generated the related path.

SOURCING DECISION BRIEF

Ultra-Low Frequency High-Voltage Generator for Electric Cable and Motor Insulation Test sourcing decision brief

Laboratory detail pages should help buyers judge whether one instrument or consumable fits the intended workflow, validation scope and environment before RFQ.

Category
Microscopes
Price status
Quote on request
Inquiry model
Structured product RFQ with quantity, destination and technical requirements.
Availability
Confirm by inquiry
Sourcing lens
Workflow-fit laboratory decision
Primary compare
Category, Brand, Unit
Adjacent category
Microscopes and Optical Equipment
Next route
Microscopes and Optical Equipment RFQ Tags
Buyer checklist
  • Workflow fit: Confirm sample type, workflow stage and operating environment before supplier outreach.
  • Validation fit: Compare accuracy, documentation and compliance needs before RFQ.
  • Technical handoff: Carry validation scope, environment and documentation requirements into the inquiry.
How should buyers use this LabInstSource detail page?

Use the detail page to confirm one instrument or consumable against the intended workflow before opening an RFQ.

What should buyers compare first?

Compare sample type, accuracy, environment and the nearest procurement or knowledge route.

LabInstSource related sourcing paths

LabInstSource procurement phrases

LabInstSource project-fit checks

Measurement Range Confirm Measurement Range before comparing offers or moving the inquiry forward.
Accuracy Confirm Accuracy before comparing offers or moving the inquiry forward.
Sample Type Confirm Sample Type before comparing offers or moving the inquiry forward.
Certification Confirm Certification before comparing offers or moving the inquiry forward.
Application route Use Application to compare adjacent options instead of relying on one broad title match.
Country route Use Country to compare adjacent options instead of relying on one broad title match.

LabInstSource related product samples

Technical validation sourcing method

Workflow fitReview the instrument or consumable against the target workflow before comparing offers.
Validation contextUse accuracy, sample type and environment requirements to filter low-fit options.
Procurement RFQSend validation, certification and operating-environment details through the inquiry path.

Procurement notes

If visible specifications are still thin, add model, material, interface, quantity, application fit, destination and target lead time before comparing quotes.

Next sourcing actions