LabInstSourceLab instruments, testing equipment, balances, microscopes, cleanroom products, and technical sourcing support for global buyers.
Temperature and Humidity Test Machine/ Climate Chamber
Fume Hoods

Temperature and Humidity Test Machine/ Climate Ch | RFQ Sourcing Details

Fume Hoods · Quote on request

This is a product procurement detail page: check specs, images, category context and related sourcing paths before sending an RFQ.

Quote on request

Product specs

CategoryFume Hoods
Unitset
OriginChina
HS Code9024
Load WayElectronic Load
MaterialSUS#304 Stainless Steel
StandardParameters
WarrantyOne Year
CategoryFume Hoods
AvailabilityInquiry required
Updated2026-05-27

Buyer's Digest

Use this page as a product-first sourcing checkpoint before sending an RFQ. Category: Fume Hoods. Confirm application fit, capacity, materials, destination, lead time and compliance requirements before comparing suppliers.

Original product description

Product Introduction: Environmental Test Chamber is suitable for Testing material heat,cold,dry,resistance,humidity,resistance. Suitablefor electronics, electrical appliances,Communications, instrumentation, vehicles, plastic products, metal, chemical,building materials, medical, aerospaceand other products.

Standard Parameters: Model HD-E702-150K20 Capacity 150L Internal dimensions 500mm*600mm*500mm(W*H*D) External dimensions 800mm*1530mm*1420mm(W*H*D) Temperature Range -20ºC ~ + 150ºC Humidity Range 20%~98%RH Temperature resolution 0.01ºC Humidity resolution 0.1%R.H Temperature deviation ±0.5ºC Humidity deviation ±2%R.H Temperature uniformity = 3ºC / min(-20ºC → + 150ºC) Cooling rate >= 1ºC / min(150ºC → -20ºC) Compressor Imported French Taikang fully enclosed compressor Refrigerant Environmental protection refrigerant R404A/R23 Cooling method Single-stage cooling Blower Centrifugal fan with forced circulation Evaporator Finned tube heat exchanger Condensation method Air-cooled Condenser Air-cooled scale condenser, cooling fan cooling Filter drier Absorbs residual moisture and acidic substances in the refrigerant of the refrigeration system, and filters out solid rest particles and copper shavings in the system to protect the normal operation of the expansion valve and capillary from ice and dirty plugging Humidification system Stainless steel humidifier Heating system Nickel chromium alloy stainless steel heater Water supply system Front-mounted water supply tank, automatic water supply system Controller Taiwan Visuo Controller Setting method Chinese / English interface, touch input Operation mode Program method / fixed value method Predetermined area Maximum temperature range: 5 ºC Storage function Standard configuration 2G SD card to record test data curve, can upload and download data, expand storage capacity Safety protection measures The overall equipment is over temperature, the fan is overheated, the overall equipment is under-phase / reverse-phase, the refrigeration system is overloaded, the refrigeration unit is over-pressured, the overall equipment timing, leakage, operation indication, automatic shutdown after failure alarm, etc.

Case shell High-quality cold-rolled

Temperature | Applications and Buyer Notes

Temperature is organized as a sourcing-ready Fume Hoods reference. The page combines visible product or company data with structured procurement cues so buyers can compare application fit, specifications, quantity, quality requirements and lead-time questions

Applications

  • Initial shortlist building for related product or supplier options.
  • Specification and application fit review before bulk purchasing.
  • Category, keyword and detail-page comparison before sending an RFQ.

Key specifications

Category
Fume HoodsBased on visible page data; confirm exact value in the RFQ.
Unit
setBased on visible page data; confirm exact value in the RFQ.
Origin
ChinaBased on visible page data; confirm exact value in the RFQ.
HS Code
9024Based on visible page data; confirm exact value in the RFQ.
Load Way
Electronic LoadBased on visible page data; confirm exact value in the RFQ.
Material
SUS#304 Stainless SteelBased on visible page data; confirm exact value in the RFQ.
Standard
ParametersBased on visible page data; confirm exact value in the RFQ.
Warranty
One YearBased on visible page data; confirm exact value in the RFQ.

Buyer tips

  • State quantity range and split-delivery needs before price comparison.
  • Add certification, material or inspection standards when they affect acceptance.
  • For time-sensitive projects, include target arrival date and destination.
  • For special applications, describe operating condition, installation environment and duty cycle.

FAQ

What should buyers confirm first?

Confirm application, specification, quantity, destination and lead-time requirements before comparing offers.

Can buyers inquire when specs are incomplete?

Yes. Add model, material, size, use case and inspection needs in the RFQ to make replies comparable.

How should this listing be evaluated?

Check title, category, specifications and related keywords against the actual sourcing requirement.

Source mix: ugc

Key specifications

CategoryFume Hoods
Unitset
OriginChina
HS Code9024
Load WayElectronic Load
MaterialSUS#304 Stainless Steel
StandardParameters
WarrantyOne Year
Model NO.HD-E702-150K20
TrademarkHaida
RefrigerantEnvironmental Protection
Power SourceAC 220V
Product NameTemperature Humidity Test Chamber
CertificationCE, TUV, ISO
SpecificationISO 9001: 2008
Transport PackageStrong Wooden Case
Exterior Dimension(W* D* H)800mm*1530mm*1420mm
Interior Dimension(W* D* H)500mm*600mm*500mm

Product sourcing keywords

These terms come from the title, visible copy and specifications, and link into matching aggregate pages.

Continue from this detail page into sourcing structure

These links connect the detail page back to category hubs, procurement aggregates and knowledge pages so new inventory is not isolated.

LabInstSource related sourcing paths

LabInstSource procurement phrases

LabInstSource related product samples