LabInstSourceLab instruments, testing equipment, balances, microscopes, cleanroom products, and technical sourcing support for global buyers.
Sh/T0219/Jisk2242 Oxidation Characteristics of Inhibited Mineral Oils Tester
Moisture Analyzers

Sh/T0219/Jisk2242 Oxidation Characteristics of In | RFQ Sourcing Details

Moisture Analyzers · Quote on request

This is a product procurement detail page: check specs, images, category context and related sourcing paths before sending an RFQ.

Quote on request

Product specs

CategoryMoisture Analyzers
Unitset
CategoryMoisture Analyzers
AvailabilityInquiry required
Updated2026-05-26

Buyer's Digest

Use this page as a product-first sourcing checkpoint before sending an RFQ. Category: Moisture Analyzers. Confirm application fit, capacity, materials, destination, lead time and compliance requirements before comparing suppliers.

Original product description

Product Overview Oxidation Characteristics of Inhibited Mineral Oils Tester This instrument is suitable for determining the oxidative stability of unused mineral insulating oils with inhibitors, and can also be used for the tendency of unused mineral insulating oils to form acids and precipitates before and after the induction period.

Mechanism: The sample was kept at 120°C in the presence of the copper catalyst coil, while a constant flow of oxygen was passed through, and the time required for the volatile acid generated by the oxidation of the sample to increase to a neutralization value equivalent to 0.28 gKOH/g was measured.

The oxidative stability of the sample is represented by the induction period (h). FEATURES AT A GLANCE Oxidation Characteristics of Inhibited Mineral Oils Tester 1. Metal bath heating, safe and environmentally friendly;2. Microcomputer temperature controller, digital display, accuracy ±0.1 PT100 sensor;3.

Precision flow meter controls the flow of gas;4. Six tests can be done at the same time, and each of the two groups is three samples;5. Digital display working time;6. The glass test tube meets the standard requirements;7. High-power solid-state relay controls heating;8. Over temperature alarm.

No Item Data 1 Applicable standard SH/T0219, JISK2242 2 Temperature control method High-quality PID digital temperature controller 3 Temperature control accuracy 180±0.1 4 Heating method Oil bath heating 5 Timing method Digital display timer 6 Working unit 6 tubes 7 Flow control Precision flow meter 8 Working power supply 220,240V 50,60.

Hz SALES AND SERVICE NETWORK SIMILAR PRODUCTS Company Profile Hunan Addition Instruments and Apparatus Co., Ltd. integrates researching,manufacturing and selling of petrochemical analysis instruments into a whole. Established in 2008 for research and development, and established as a sales department in 2015.

Addition not only maintains the tradition of stable analytical instrument performance and exquisite craftsmanship, but also improves product performance and accuracy, and makes our products more in t of "Innovation and Excellence", and uses unremitting efforts and wisdom to provide customers with high-quality products.

Our company has served thousands of co

Sh | Applications and Buyer Notes

Sh is organized as a sourcing-ready Moisture Analyzers reference. The page combines visible product or company data with structured procurement cues so buyers can compare application fit, specifications, quantity, quality requirements and lead-time questions b

Applications

  • Initial shortlist building for related product or supplier options.
  • Specification and application fit review before bulk purchasing.
  • Category, keyword and detail-page comparison before sending an RFQ.

Key specifications

Category
Moisture AnalyzersBased on visible page data; confirm exact value in the RFQ.
Unit
setBased on visible page data; confirm exact value in the RFQ.

Buyer tips

  • State quantity range and split-delivery needs before price comparison.
  • Add certification, material or inspection standards when they affect acceptance.
  • For time-sensitive projects, include target arrival date and destination.
  • For special applications, describe operating condition, installation environment and duty cycle.

FAQ

What should buyers confirm first?

Confirm application, specification, quantity, destination and lead-time requirements before comparing offers.

Can buyers inquire when specs are incomplete?

Yes. Add model, material, size, use case and inspection needs in the RFQ to make replies comparable.

How should this listing be evaluated?

Check title, category, specifications and related keywords against the actual sourcing requirement.

Source mix: ugc

Key specifications

CategoryMoisture Analyzers
Unitset

Product sourcing keywords

These terms come from the title, visible copy and specifications, and link into matching aggregate pages.

Continue from this detail page into sourcing structure

These links connect the detail page back to category hubs, procurement aggregates and knowledge pages so new inventory is not isolated.

LabInstSource related sourcing paths

Related applications LabInstSource related paths

Quality Control Labs

Materials and Industrial Analysis

Pharma and Biotech Testing

Related solutions LabInstSource related paths

High Precision Lab Setup

Cleanroom Monitoring and Supplies

LabInstSource procurement phrases

LabInstSource related product samples