Real Time PCR for DNA Testing Equipment on Made i | RFQ Sourcing Details
Pcr Machines · Quote on request
This is a product procurement detail page: check specs, images, category context and related sourcing paths before sending an RFQ.
Product specs
Buyer's Digest
Use this page as a product-first sourcing checkpoint before sending an RFQ. Category: Pcr Machines. Confirm application fit, capacity, materials, destination, lead time and compliance requirements before comparing suppliers.
Original product description
The Gentier 48E real-time quantitative PCR detection system can be used for universal 48-well 4-color fluorescence detection, and each tube can detect 4 items at the same time, which greatly improves the experimental efficiency and avoids the inconvenience caused by repeated sample detection.
Application areas include rapid food safety testing, on-site public health testing, small and medium-sized scientific research laboratories, and POCT. Features 1. Temperature control: The maximum heating rate is up to 8 ° C / s, and the maximum cooling rate is up to 6.1 ° C / s.
It only takes 30min to complete a standard PCR amplification procedure, which can realize your rapid detection;the temperature accuracy is controlled within ± 0.1 ° C To ensure good repeatability and accuracy. 2. Fluorescence scan: It takes only 2s to complete all 48-well 4-color fluorescence scans.
For users who need to use the high-resolution melting curve (HRM) function, it can significantly reduce the overall test time and greatly improve work efficiency. 3.
Built-in 7-inch full-color touch screen, independent control system and USB data export function, without the need to connect to a computer, the entire experiment can be completed in a single machine operation. 4. Full Chinese system interface and wizard-based parameter setting.
After simple training, you can fully grasp the standard use of the instrument and quickly have the ability to independently operate experiments. 5. Standard network interface, through the setting of network parameters, can realize remote operation, experiment monitoring and data transmission in LAN. 6.
Multi-use in one machine: In addition to conventional analysis functions such as relative quantification, absolute quantification, HRM, and SNP, it is more compatible with a variety of isothermal amplification technologies for fluorescence analysis and truly realizes one machine for multiple uses. 7.
Complex data analysis: In addition to the instrument operation software, it is also equipped with a set of independent data management software to achieve centralized management, statistics, and analysis of users' massive experimental data, reducing errors caused by complex analysis of the original data manually. 8.
Universal report function: The built-in universal report function can adjust and customize the experimental report format according to the needs of different users, and establish its own unique experimental report style. 9. Small size, light weight, easy to carry, can be moved to the required place or equipped to a 10.
Using a fixed fluorescence detection unit, no need to perform any calibration work after moving, it can be started directly. Specification Model Gentier 48E Detection flux 0.2ml transparent 48-well plate without skirt, octaplex tube, single tube, etc. Applicable dyes / probes Channel 1: FAM, SYBR Green I, etc.
Channel 2: VIC, HEX, TET, JOE, etc. Channel 3: ROX, Texas Red, etc. Channel 4: Cy5, etc. Reaction system 5μl~100μl Power Specifications AC 220V(±10%),50.
Hz,600VA Communication Interface Ethernet (RJ45), USB Weight 11 Kg Dimensions 260*400*260mm(W*L*H) Temperature Control System / Temperature control technology Semiconductor refrigeration chip heating and cooling technology Temperature control range 0.0℃~100.0℃ Temperature accuracy ≤ 0.1℃ Module temperature control accuracy ≤ 0.1℃ Temperature uniformity ±0.1℃ Heating rate 8℃/s Average heating rate 6.1℃/s Cooling rate 6.1℃/s Average cooling rate 4.0℃/s Temperature gradient support Gradient range 35℃~100℃ Gradient span 1℃~40℃ Temperature control program Supports standard PCR, gradient PCR, landing PCR, long fragment PCR, etc.
Temperature range of hot lid 40℃~110℃ Optical system / Excitation light source Highlight maintenance-free LED Fluorescence detection device Photodiode Fluorescence scan time 48-hole 4-color detection in 2s Excitation wavelength Channel 1: 470nm Channel 2: 523nm Channel 3: 571nm C
Real | Applications and Buyer Notes
Real is organized as a sourcing-ready Pcr Machines reference. The page combines visible product or company data with structured procurement cues so buyers can compare application fit, specifications, quantity, quality requirements and lead-time questions befor
Applications
- Initial shortlist building for related product or supplier options.
- Specification and application fit review before bulk purchasing.
- Category, keyword and detail-page comparison before sending an RFQ.
Key specifications
- Category
- PCR MachinesBased on visible page data; confirm exact value in the RFQ.
- Unit
- setBased on visible page data; confirm exact value in the RFQ.
- color
- detection in 2s Excitation wavelength Channel 1: 470nm Channel 2: 523nm ChannelBased on visible page data; confirm exact value in the RFQ.
- standard
- use of the instrument and quickly have the ability to independently operate expeBased on visible page data; confirm exact value in the RFQ.
- interface
- and wizard-based parameter setting. After simple training, you can fully grasp tBased on visible page data; confirm exact value in the RFQ.
Buyer tips
- State quantity range and split-delivery needs before price comparison.
- Add certification, material or inspection standards when they affect acceptance.
- For time-sensitive projects, include target arrival date and destination.
- For special applications, describe operating condition, installation environment and duty cycle.
FAQ
What should buyers confirm first?
Confirm application, specification, quantity, destination and lead-time requirements before comparing offers.
Can buyers inquire when specs are incomplete?
Yes. Add model, material, size, use case and inspection needs in the RFQ to make replies comparable.
How should this listing be evaluated?
Check title, category, specifications and related keywords against the actual sourcing requirement.
Source mix: ugc
Key specifications
Product sourcing keywords
These terms come from the title, visible copy and specifications, and link into matching aggregate pages.
Continue from this detail page into sourcing structure
These links connect the detail page back to category hubs, procurement aggregates and knowledge pages so new inventory is not isolated.
This URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path Automatic Medical Cleaning Machine Medical Instrument Washing Sterilizer Disinfection DeviceThis URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path Best Quality Low Price Steel Wood Physics High School Chemistry Island Laboratory Furniture Jh SlThis URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path Colourful New Design Laboratory Furniture Jh Sl061 Laboratory Furniture And Steel Lab FurnitureThis URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path Cleanroom Monitoring Systems sourcing pathThis URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path Cleanroom Product Suppliers sourcing pathThis URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path Digital Inspection Microscopes sourcing pathThis URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path 10 98 Low Humidity Type Temperature Humidity Environmental Climate Test Chamber For Lab LaboratoThis URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path 100l Pep De Synthesizer Technical SpecificationsThis URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path 16500rpm High Speed Capillary Hematocrit Centrifuge For Hospital Medical Use Hematocrit CentrifugeThis URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path 2 8 Degree Biomedical Vaccine Pharmacy Refrigerator Plasma Freezer For LabThis URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path 2021 New Type Lab Centrifuge Xld900 1This URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path 252l Programmable Three Zones Thermal Shock Test Machine Environmental Could And Hot Thermal TesterThis URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path 3e Blood Harvest Prp Centrifuge Kit For Lab 3e Blood Harvest Prp Centrifuge Kit And Prp CentrifugeThis URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
LabInstSource related sourcing paths
Sample Preparation and Lab Basics
LabInstSource procurement phrases
LabInstSource related product samples
We are a manufacturer specializing in the R&D of laboratory electric heating equipment. Our process is unique worldwide,...
Sample Preparation and Lab Basics Semi-Exhaust Type Biological Safety Cabinet Machine Medical Equipment - Medical Equipment and MedicaSemi-exhaust type biological safety cabinet school laboratory 1.Description The biosafety cabinet protects both human sa...
Sample Preparation and Lab Basics Etcolabs PP Fume Hood - Compliant with En 14175 Ashrae mm - 2026 Fume Hood, En 14175 FuIn the domain of laboratory safety, our fume hoods stand as indispensable protectors, catering to the rigorous demands o...
Sample Preparation and Lab Basics Laboao InUsing American Marlow semiconductor refrigeration sheet, the maximum temperature change rate is more than 5 degrees per ...
Sample Preparation and Lab Basics Erun-Sp9-B6 High-Accuracy Turbidimeter Laboratory-Grade Tool for Industrial Water Quality TestingIntroduction This instrument features 16 channels for the optical method and can measure over 60 parameters, as well as ...
Sample Preparation and Lab Basics Cordial Lab 5-5000ml Borosilicate 3.3 Glass Low Form Beaker for Lab Use - Glass Beaker and Low Form: With Spout and graduations 4. Color: Clear-to-read white enamel graduated scale. 2) Borosilicate tubing made and machi...