LabInstSourceLab instruments, testing equipment, microscopes, balances, and cleanroom supplies
Pilotech Lab Spray Dryer Yc-019 for Pharmaceutical Research
Special Equipment For Laboratory

Pilotech Lab Spray Dryer Yc-019 for Pharmaceutical Research

Laboratory detail pages should help buyers judge whether one instrument or consumable fits the intended workflow, validation scope and environment before RFQ.

Quote on request

Product sourcing profile

CategorySpecial Equipment For Laboratory
Inquiry workflowPlatform RFQ workflow
AvailabilityInquiry required
Updated2026-05-04

Product introduction

Home Industrial Equipment & Components Drying Machine Spray Drying Machine Laboratory Spray Dryer Pilotech Lab Spray Dryer Yc-019 for Pharmaceutical Research US$14, ,352.00 1 unit-led product discovery for buyers looking for laboratory equipment options. The page is organized around specification review, application fit, and inquiry-ready comparison.When evaluating this product, buyers should confirm application fit, required performance range, installation environment, lead time, documentation, and whether the supplier can support OEM or project quotations. Current vertical focus: laboratory instrument sourcing, testing equipment discovery, and rfq-ready lab supply platform.laboratory

Selection and RFQ points

Review material fit, application context, alternatives and RFQ detail before comparing related product paths.

Material fit Special Equipment

Confirm material, size, finish, tolerance and processing needs before price comparison.

Application fit application, operating environment and usage frequency

Add the target application and operating context so related products can be compared correctly.

Alternative path Laboratory Equipment

Use nearby materials, equipment types or category pages when this record is close but not exact.

RFQ detail Quantity, destination, timing

Include quantity, destination, target delivery window, packaging and any technical constraints.

LabInstSource quality checks

Workflow contextConfirm whether the item fits the intended lab, QC or cleanroom workflow.

Use this check before moving from discovery into product comparison or RFQ submission.

Validation requirementCheck sample type, accuracy, environment and certification needs before comparing offers.

Use this check before moving from discovery into product comparison or RFQ submission.

Procurement detailBring validation scope, operating environment and documentation requirements into the RFQ.

Use this check before moving from discovery into product comparison or RFQ submission.

Key specifications

CategoryLaboratory Equipment
Brand
Unitset
10Nozzle type Two fluid nozzle
11Nozzle tip diameter 2.0mm standard/(0.5/0.8/1.0/1.5 available)
12Possible particle sizerange 1-100µm
13Max. Sample feed 5000ml/hr
14Min.sample volume 100ml (related to factors such as the solid content of the material)
15Atomizer material SUS 316 Stainless steel
16Spray chamber material SUS304 Stainless steel
17Cyclone separator material SUS304 Stainless steel
18Receiving tank material SUS304 Stainless steel
19Body material SUS304 Stainless steel
20Seal of cyclone/cylinder Silicone
21Deblocking Automatic
22Display 7-Inch LCD touch screen displays inlet air temperature, blower frequency, needle frequency, peristaltic pump speed
23Inert loop (for organic solvents) Optional(Please specify in advance when ordering)
After-sales ServiceOnline Support, Video Technical Support
Air Inlet TemperatureMax 300°C
ApplicationFood and beverage processing
AtomizationGas Atomization
Atomizer MaterialSUS 316 Stainless Steel
Body MaterialSUS304 Stainless Steel
Capacity5000ml/Hr
CategoryLaboratory Equipment
CustomizationAvailable
DeblockingAutomatic
Display7-Inch LCD Touch Screen Displays Inlet Air Tempera
Feature Highlightsstainless steel, digital, automatic, precision
FlowAir Flow
Flow Rate64l/min
Heat SourceElectricity
Heater Power9kw
Heating ModeElectric Heating
Inert Loop (for Organic Solvents)Optional (Please Specify in Advance When Ordering)
Matched Termslaboratory
Material StatusSolution
Min. Sample Volume100ml
Model NO.YC-019
Nozzle Tip Diameter2.0mm Standard/(0.5/0.8/1.0/1.5 Available)
Nozzle TypeTwo Fluid Nozzle
OriginShanghai
Possible Particle Size Range1-100μm
Power12kw
Product TitlePilotech Lab Spray Dryer Yc-019 for Pharmaceutical Research
Sr.noParameter Pilotech YC-019 pilot spray dryer
Temperature300°c
Temperature Precision±2°C
TrademarkPilotech
Transport PackageTriply Wood
TypeAirflow Spray
US$14,411.00-17,352.001 unit (MOQ)
Voltage380V;Three-Phase Five-Wire
Warranty1 Year

Keyword evidence

Only terms with visible evidence in this listing are shown here.

Product sourcing keywords

These terms come from the title, visible copy and specifications, and link into matching aggregate pages.

Related keyword paths

Grouped by the product keyword that generated the related path.

SOURCING DECISION BRIEF

Pilotech Lab Spray Dryer Yc-019 for Pharmaceutical Research sourcing decision brief

Laboratory detail pages should help buyers judge whether one instrument or consumable fits the intended workflow, validation scope and environment before RFQ.

Category
Laboratory Equipment
Price status
Quote on request
Inquiry model
Structured product RFQ with quantity, destination and technical requirements.
Availability
Confirm by inquiry
Sourcing lens
Workflow-fit laboratory decision
Primary compare
Category, Brand, Unit
Adjacent category
Sample Preparation and Lab Basics
Next route
Sample Preparation and Lab Basics RFQ Tags
Buyer checklist
  • Workflow fit: Confirm sample type, workflow stage and operating environment before supplier outreach.
  • Validation fit: Compare accuracy, documentation and compliance needs before RFQ.
  • Technical handoff: Carry validation scope, environment and documentation requirements into the inquiry.
How should buyers use this LabInstSource detail page?

Use the detail page to confirm one instrument or consumable against the intended workflow before opening an RFQ.

What should buyers compare first?

Compare sample type, accuracy, environment and the nearest procurement or knowledge route.

LabInstSource related sourcing paths

LabInstSource procurement phrases

LabInstSource project-fit checks

Measurement Range Confirm Measurement Range before comparing offers or moving the inquiry forward.
Accuracy Confirm Accuracy before comparing offers or moving the inquiry forward.
Sample Type Confirm Sample Type before comparing offers or moving the inquiry forward.
Certification Confirm Certification before comparing offers or moving the inquiry forward.
Application route Use Application to compare adjacent options instead of relying on one broad title match.
Country route Use Country to compare adjacent options instead of relying on one broad title match.

LabInstSource related product samples

Technical validation sourcing method

Workflow fitReview the instrument or consumable against the target workflow before comparing offers.
Validation contextUse accuracy, sample type and environment requirements to filter low-fit options.
Procurement RFQSend validation, certification and operating-environment details through the inquiry path.

Procurement notes

If visible specifications are still thin, add model, material, interface, quantity, application fit, destination and target lead time before comparing quotes.

Next sourcing actions