LabInstSourceLab instruments, testing equipment, balances, microscopes, cleanroom products, and technical sourcing support for global buyers.
Pharmaceutical Packaging Seal Integrity Testing, Micro Vacuum Decay Leak Tester
Laboratory Workbenches

Pharmaceutical Packaging Seal Integrity Testing, | RFQ Sourcing Details

Laboratory Workbenches · Quote on request

This is a product procurement detail page: check specs, images, category context and related sourcing paths before sending an RFQ.

Quote on request

Product specs

CategoryLaboratory Workbenches
Unitset
Powersource 220V 50Hz Air source pressure nothing ≥0.5MPa Air source
OriginJinan Shandong
Weight0-100Kg
DisplayDigital
Warranty12 Months
Model NO.MLT-V100
CategoryLaboratory Workbenches
AvailabilityInquiry required
Updated2026-06-01

Buyer's Digest

Use this page as a product-first sourcing checkpoint before sending an RFQ. Category: Laboratory Workbenches. Confirm application fit, capacity, materials, destination, lead time and compliance requirements before comparing suppliers.

Original product description

. . Model NO. MLT-V100 Display Digital Control Computer Control Weight 0-100.

Kg Power Source AC220V Testing Methods Pressure Differential Vacuum, Positive Pressure at Testing System Multi Sensor Technology Vacuum Range 0~-100kpa/0~-14.5psi/0~-1000mbar Testing Accuracy 0.01CCM Minimum Testing Unit Mbar/PA/Psi Testing Time 5-30s Operation Interface 7-Inch LCD Touch Screen Vacuum Resolution 1PA/0.01mbar/0.0001psi Data Transfer USB/485 Communication Data Storage Excel Form Administration Three Level Administration Security Keys Yes Vacuum Source External Electric Vacuum Pump Testing Results by / Not by Automatic Judgment Testing Standards ASTM F2338 Transport Package Wooden Packaging Specification MLT- V100(L) Trademark paratronix Origin Jinan Shandong Production Capacity 10000tower/Year Packaging & Delivery Package Size 32.00cm * 52.00cm * 32.00cm Package Gross Weight 60.000kg The MLT series of micro leakage non-destructive sealing tester is developed according to ASTM F Standard Test Method for Packaging Leakage - Vacuum Attenuation Method.

Professional for all kinds of empty/pre-filled Non-destructive positive and negative pressure microleakage testing of syringes, water and powder bottles (glass/plastic), filling and pressing bottles, milk powder cans, other rigid packaging containers, electrical components, etc.

This product adopts advanced design and rigorous, scientific calculation method to ensure its rapid testing and high accuracy and high stability. Non-standard customization (software or test fixture) can also be met.

Leakage testing methods comparison Comparison test Water bath test Micro-leakage detection The smallest aperture that can be detected 10~20μm 30s Around 10s Display value management quantification Sensory tests, difficult to quantify Leakage quantity and leak aperture Value reproduction Poor repeatability Value reproduction available Destructive/non-destructive Destructive test Non-destructive test Testing medium Water (requires maintenance) Air Human error Small leakage, difficult to detect Value management, no manual Leaking point confirmation Leakages can be located Leaking point can't be confirmed Parameters MLT-V100 MLT-V100(T) MLT-V100(P) Test method Vacuum attenuation method Vacuum attenuation method/pressure attenuation method Measurement and control Microcomputer, dual sensor test technology Vacuum system Vacuum pump Barotropic system nothing External air source Test unit k.

Pa/mbar/psi/Pa Resolution 1. Pa 0.1. Pa Test range -99~0k. Pa -99~400k. Pa Measuring range ≥0.01ccm (about1μm ) Test accuracy ±0.2μm (≥3μm ) Test accuracy ±0.3μm (

Pharmaceutical | Applications and Buyer Notes

Pharmaceutical is organized as a sourcing-ready Laboratory Workbenches reference. The page combines visible product or company data with structured procurement cues so buyers can compare application fit, specifications, quantity, quality requirements and lead-

Applications

  • Initial shortlist building for related product or supplier options.
  • Specification and application fit review before bulk purchasing.
  • Category, keyword and detail-page comparison before sending an RFQ.

Key specifications

Category
Laboratory WorkbenchesBased on visible page data; confirm exact value in the RFQ.
Unit
setBased on visible page data; confirm exact value in the RFQ.
Power
source 220V 50Hz Air source pressure nothing ≥0.5MPa Air sourceBased on visible page data; confirm exact value in the RFQ.
Origin
Jinan ShandongBased on visible page data; confirm exact value in the RFQ.
Weight
0-100KgBased on visible page data; confirm exact value in the RFQ.
Display
DigitalBased on visible page data; confirm exact value in the RFQ.
Warranty
12 MonthsBased on visible page data; confirm exact value in the RFQ.
Model NO.
MLT-V100Based on visible page data; confirm exact value in the RFQ.

Buyer tips

  • State quantity range and split-delivery needs before price comparison.
  • Add certification, material or inspection standards when they affect acceptance.
  • For time-sensitive projects, include target arrival date and destination.
  • For special applications, describe operating condition, installation environment and duty cycle.

FAQ

What should buyers confirm first?

Confirm application, specification, quantity, destination and lead-time requirements before comparing offers.

Can buyers inquire when specs are incomplete?

Yes. Add model, material, size, use case and inspection needs in the RFQ to make replies comparable.

How should this listing be evaluated?

Check title, category, specifications and related keywords against the actual sourcing requirement.

Source mix: ugc

Key specifications

CategoryLaboratory Workbenches
Unitset
Powersource 220V 50Hz Air source pressure nothing ≥0.5MPa Air source
OriginJinan Shandong
Weight0-100Kg
DisplayDigital
Warranty12 Months
Model NO.MLT-V100
Test unitkPa/mbar/psi/Pa
Trademarkparatronix
interfaceφ6mm TU tube Appearance
ParametersMLT-V100 MLT-V100-V100
Resolution1Pa 0.1Pa
Test range99~0kPa-99~400kPa
Audit trailSupport
Human errorSmall leakage, difficult to detect Value management, no manual
Test methodVacuum attenuation method Vacuum attenuation method/pressure attenuation method
Data StorageExcel Form
Data storage600groups Unlimited
Package Size32.00cm * 52.00cm * 32.00cm
Power SourceAC220V
Power source220V 50Hz
Testing Time5-30s
Testing UnitMbar/PA/Psi
Testing time>30s Around 10s
Vacuum Range0~-100kpa/0~-14.5psi/0~-1000mbar
CustomizationAvailable
Data TransferUSB/485 Communication
Refund policyClaim a refund if your order doesn't ship, is missing, or arrives with product issues.
Security KeysYes
Shipping Cost.
SpecificationMLT-V100
Test accuracy±0.2μm (≥3μm )
Vacuum SourceExternal Electric Vacuum Pump
Vacuum systemVacuum pump
AdministrationThree Level Administration
Control systemSingle-chip system Windowssystem
Reporting modeMicroprinter Microprinter/A4 report A4 report
Testing SystemMulti Sensor Technology
Testing mediumWater (requires maintenance) Air
Comparison testWater bath test Micro-leakage detection
Testing MethodsPressure Differential Vacuum, Positive Pressure at
Testing Resultsby / Not by Automatic Judgment
Equipment weightabout20kg
Testing Accuracy0.01CCM Minimum
Barotropic systemnothing External air source
Data transmissionUSB/RS232/485
Main control chipSTMMicrocomputer chip
Overall dimension320(L)×480(W)×320(H)mm 340(L)×480(W)×320(H)mm 340(L)×470(W)×320(H)mm
Testing StandardsASTM F2338
Transport PackageWooden Packaging
Vacuum Resolution1PA/0.01mbar/0.0001psi
Keyboard and mouseNonsupport Support
Value reproductionPoor repeatability Value reproduction available
After-sales Serviceon Line
Air source pressurenothing ≥0.5MPa
Appearance materialEngineering plastics/stainless steel
Operation Interface7-Inch LCD Touch Screen
Production Capacity10000tower/Year
Air source interfaceφ6mm TU tube
Package Gross Weight60.000kg
Acquisition frequency50~200Hz
Fixture configurationManual/automatic fixture
US$3, ,000.001 Set ( )
Measurement and controlMicrocomputer, dual sensor test technology
Destructive/non-destructiveDestructive test Non-destructive test
Display value management quantificationSensory tests, difficult to quantify Leakage quantity and leak aperture
The smallest aperture that can be detected10~20μm

Product sourcing keywords

These terms come from the title, visible copy and specifications, and link into matching aggregate pages.

Continue from this detail page into sourcing structure

These links connect the detail page back to category hubs, procurement aggregates and knowledge pages so new inventory is not isolated.

LabInstSource related sourcing paths

LabInstSource procurement phrases

LabInstSource related product samples