LabInstSourceLab instruments, testing equipment, microscopes, balances, and cleanroom supplies
Medical Waste Microwave Disinfection Automatic Treatment Machine with Shredding System
Optical Instrument

Medical Waste Microwave Disinfection Automatic Treatment Machine with Shredding System

Laboratory detail pages should help buyers judge whether one instrument or consumable fits the intended workflow, validation scope and environment before RFQ.

Quote on request

Product sourcing profile

CategoryOptical Instrument
Inquiry workflowPlatform RFQ workflow
AvailabilityInquiry required
Updated2026-05-05

Product introduction

Medical Waste Microwave Disinfection Automatic Treatment Machine with Shredding System US$50, ,000.00 1 Set (MOQ) Start Order Request Send Inquiry Chat Now Still deciding? Get samples of $ ! US$ 2750/Set Order Sample Product Details Customization: Ava. Lab. Inst. Source curates RFQ-led product discovery for buyers looking for microscopes options. The page is organized around specification review, application fit, and inquiry-ready comparison.When evaluating this product, buyers should confirm application fit, required performance range, installation environment, lead time, documentation, and whether the supplier can support OEM or project quotations. Current vertical focus: laboratory instrument sourcing, testing equipment discovery, and rfq-ready lab supply platform.

Selection and RFQ points

Review material fit, application context, alternatives and RFQ detail before comparing related product paths.

Material fit Shredding System

Confirm material, size, finish, tolerance and processing needs before price comparison.

Application fit application, operating environment and usage frequency

Add the target application and operating context so related products can be compared correctly.

Alternative path Optical Instrument

Use nearby materials, equipment types or category pages when this record is close but not exact.

RFQ detail Quantity, destination, timing

Include quantity, destination, target delivery window, packaging and any technical constraints.

LabInstSource quality checks

Workflow contextConfirm whether the item fits the intended lab, QC or cleanroom workflow.

Use this check before moving from discovery into product comparison or RFQ submission.

Validation requirementCheck sample type, accuracy, environment and certification needs before comparing offers.

Use this check before moving from discovery into product comparison or RFQ submission.

Procurement detailBring validation scope, operating environment and documentation requirements into the RFQ.

Use this check before moving from discovery into product comparison or RFQ submission.

Key specifications

CategoryMicroscopes
Brand
Unitset
1.It is applicable to hospitals, medical testing centers, airport testing stations and customs ports. It can realize timely treatment of medical waste in isolated areas during major periods.
2.Microwave with strong penetration, thorough sterilization, blocking the spread of bacteria, to prevent the spread of the epidemic.
3.To solve the Emergency handling problem during equipment maintenance of medical waste disposal center.
4.High degree of automation, a full set of equipment can be operated by only one person, to avoid cross infection.
5.Equipment with integrated design, small footprint and low noise.
6.It can be used as a regional emergency standby facility.
7.Strong mobility, can quickly reach the epidemic area/hospital/shelter quarantine site, direct disposal on-site, reduce transport risks.
8.High degree of integration,can start operation immedia
9.No waste water, with purification device, clean discharge, no pollution.
After-sales ServiceLifelong Technical Service
ApplicationIndustrial automation and process control
AutomationAutomatic
Biological indicatorThe killing rate of Bacillus subtilis black variant spores is above 99.99%
BladeRotating disc thickness 20mm High strength, high hardness Import from Germany
Blade Thickness20mm
Capacity20kg/H
CategoryMicroscopes
CertificationGMA, QS, FDA, ISO, CE
ConditionNew
Cooling TypeAir/Water Cooling
Crusher Power15kw
CustomizationAvailable
Feature Highlightsstainless steel, digital, automatic
Feed Bin MaterialStainless Steel + Alloy Steel
Feed Bin Volume100L
Main Dimension L*W*H2000*1500*1800
MaterialStainless steel + alloy steel
Microwave Generator1.5kw*2set
Model NO.HRXS-MWT-W14
No.System Unit Item Technical Parameters Remark Brand
OriginChina
Power3 Phase 380V
Product TitleMedical Waste Microwave Disinfection Automatic Treatment Machine with Shredding System
Refund policyClaim a refund if your order doesn't ship, is missing, or arrives with product issues.
Rotate speed>1000r/min
ScrewMulti-Screw
Secure paymentsEvery payment you make on Made-China.com is protected by the platform.
Shipping Cost.
Specification20kg-10000kg microwave medical waste treatment
Total Power12kw
Total Weight1100kg
TrademarkZHITE
Transport PackageWooden Box
TreatmentChemical Treatment
US$50,000.00-170,000.001 Set (MOQ)
Voltage380v
Volume Reduction80%
Volume and weight reduction rateReduce volume by 80% and weight by 20%
Warranty1 Year
Water Consumpetion Per Cycle3L
Weight Volume20%

Keyword evidence

Only terms with visible evidence in this listing are shown here.

Product sourcing keywords

These terms come from the title, visible copy and specifications, and link into matching aggregate pages.

Related keyword paths

Grouped by the product keyword that generated the related path.

SOURCING DECISION BRIEF

Medical Waste Microwave Disinfection Automatic Treatment Machine with Shredding System sourcing decision brief

Laboratory detail pages should help buyers judge whether one instrument or consumable fits the intended workflow, validation scope and environment before RFQ.

Category
Microscopes
Price status
Quote on request
Inquiry model
Structured product RFQ with quantity, destination and technical requirements.
Availability
Confirm by inquiry
Sourcing lens
Workflow-fit laboratory decision
Primary compare
Category, Brand, Unit
Adjacent category
Microscopes and Optical Equipment
Next route
Microscopes and Optical Equipment RFQ Tags
Buyer checklist
  • Workflow fit: Confirm sample type, workflow stage and operating environment before supplier outreach.
  • Validation fit: Compare accuracy, documentation and compliance needs before RFQ.
  • Technical handoff: Carry validation scope, environment and documentation requirements into the inquiry.
How should buyers use this LabInstSource detail page?

Use the detail page to confirm one instrument or consumable against the intended workflow before opening an RFQ.

What should buyers compare first?

Compare sample type, accuracy, environment and the nearest procurement or knowledge route.

LabInstSource related sourcing paths

LabInstSource procurement phrases

LabInstSource project-fit checks

Measurement Range Confirm Measurement Range before comparing offers or moving the inquiry forward.
Accuracy Confirm Accuracy before comparing offers or moving the inquiry forward.
Sample Type Confirm Sample Type before comparing offers or moving the inquiry forward.
Certification Confirm Certification before comparing offers or moving the inquiry forward.
Application route Use Application to compare adjacent options instead of relying on one broad title match.
Country route Use Country to compare adjacent options instead of relying on one broad title match.

LabInstSource related product samples

Technical validation sourcing method

Workflow fitReview the instrument or consumable against the target workflow before comparing offers.
Validation contextUse accuracy, sample type and environment requirements to filter low-fit options.
Procurement RFQSend validation, certification and operating-environment details through the inquiry path.

Procurement notes

If visible specifications are still thin, add model, material, interface, quantity, application fit, destination and target lead time before comparing quotes.

Next sourcing actions