Product specs

CategoryAutoclaves
Unitset
ModelC.E.I OX/70-3 Inherent filter 0.5mm AL Focus point 0.3 * 0.3mm Dimension 285mm x 265mm x 168mm
power220V±10%
warrantyDetailed Photos Related prod
InterfaceTechnical
Applicationscope: Limited to X-ray diagnosis of limbs and chest. YJ-BW705 system is not suitable for mammography Operating
SpecificationCharger Input Mono-phase,AC
CategoryAutoclaves
AvailabilityInquiry required
Updated2026-05-27

Buyer's Digest

Use this page as a product-first sourcing checkpoint before sending an RFQ. Category: Autoclaves. Confirm application fit, capacity, materials, destination, lead time and compliance requirements before comparing suppliers.

Original product description

YJ-BW705 Handheld DR X-ray Machine Suitable for Comprehensive diagnostic center/Hospital radiology department/Radiological imaging center/Emergency room/Orthopedic department/Lung diagnosis center/Veterinary hospitals YJ-BW705 Handheld X-ray Machine( Built-in computer system) YJ-BW705 is a stationary X-ray imaging system used to acquire radiographic images of different parts of the human body in a clinical setting * The all-in-one device is compactand easy to carry, suitable forvarlous environments such ashospitals clinics field hospitalsremote medical services andforensic identification * Fixed exposure parameters easy to operate.

Exposure can be achieved throughbattery operation mode and the battery directly provides exposureenergy. It can be taken in any direction during shooting. * The bracket to support the deviceis optional Dimension main engmne.265.9x103.6x168.1mm(Lx. WxH)Net weight: 2.6.

Kg Application scope: Limited to X-ray diagnosis of limbs and chest. YJ-BW705 system is not suitable for mammography Operating Interface Technical specifications Project Specification Charger Input Mono-phase,AC power 220V±10% frequency 50. Hz±1. Hz Output 25.2 VDC ,1.5A Battery 22.2V(polymer lithium ion),2200m.

Ah kV (Adjustable) 50 -70 kV (step:1 kV ) mA (Adjustable) 2- 5mA (step:1 mA ) X-ray release time range [second] secs(step: 10millisecond) secs(step: 50millisecond) Screen 7 inches (resolution:1024x600) X-ray tube Model C.E.I OX/70-3 Inherent filter 0.5mm AL Focus point 0.3 * 0.3mm Dimension 285mm x 265mm x 168mm (length×width×height) Weight 3.2kg±5% Detector parameter Parameters Specifications Detector model BW-1717W BW-1717X BW-1012W Dimension(mm) 460×460×15 460×460×15 282×333×15 Effective imaging area(mm) 433.5× × ×307 Pixel matrix(pixels) 2816× × ×2560 Pixel size 154um 100um 120um Spatial resolution 3.1 Lp/mm 4.0 Lp/mm 3.7 Lp/mm Quantum detection efficiency 0.5 lp/mm 60% 65.8% 60% 1.0 lp/mm 55% 55.9% 55% 1.5 lp/mm 45% 47.5% 45% 2.0 lp/mm 40% 40.4% 40% 2.5 lp/mm 30% 34.3% 30% Battery 14.8V,capacity 3260m.

Ah 11.55V, capacity 4900m. Ah 14.8V,capacity 3260m. Ah Power Max. 36 VA Max.40 VA Max. 38 VA Weight About 4.1kg 3.3kg 2.3kg COMPATIBLE DETECTORSAND ACQUISITION SOFTWARE Optional Wireless Flat Panel Detector --- Portable --- Adaptable --- Fast --- Easy --- One year warranty Detailed Photos Related prod

Medical | Applications and Buyer Notes

Medical is organized as a sourcing-ready Autoclaves reference. The page combines visible product or company data with structured procurement cues so buyers can compare application fit, specifications, quantity, quality requirements and lead-time questions befo

Applications

  • Initial shortlist building for related product or supplier options.
  • Specification and application fit review before bulk purchasing.
  • Category, keyword and detail-page comparison before sending an RFQ.

Key specifications

Category
AutoclavesBased on visible page data; confirm exact value in the RFQ.
Unit
setBased on visible page data; confirm exact value in the RFQ.
Model
C.E.I OX/70-3 Inherent filter 0.5mm AL Focus point 0.3 * 0.3mm Dimension 285mm xBased on visible page data; confirm exact value in the RFQ.
power
220V±10%Based on visible page data; confirm exact value in the RFQ.
warranty
Detailed Photos Related prodBased on visible page data; confirm exact value in the RFQ.
Interface
TechnicalBased on visible page data; confirm exact value in the RFQ.
Application
scope: Limited to X-ray diagnosis of limbs and chest. YJ-BW705 system is not suiBased on visible page data; confirm exact value in the RFQ.
Specification
Charger Input Mono-phase,ACBased on visible page data; confirm exact value in the RFQ.

Buyer tips

  • State quantity range and split-delivery needs before price comparison.
  • Add certification, material or inspection standards when they affect acceptance.
  • For time-sensitive projects, include target arrival date and destination.
  • For special applications, describe operating condition, installation environment and duty cycle.

FAQ

What should buyers confirm first?

Confirm application, specification, quantity, destination and lead-time requirements before comparing offers.

Can buyers inquire when specs are incomplete?

Yes. Add model, material, size, use case and inspection needs in the RFQ to make replies comparable.

How should this listing be evaluated?

Check title, category, specifications and related keywords against the actual sourcing requirement.

Source mix: ugc

Key specifications

CategoryAutoclaves
Unitset
ModelC.E.I OX/70-3 Inherent filter 0.5mm AL Focus point 0.3 * 0.3mm Dimension 285mm x 265mm x 168mm
power220V±10%
warrantyDetailed Photos Related prod
InterfaceTechnical
Applicationscope: Limited to X-ray diagnosis of limbs and chest. YJ-BW705 system is not suitable for mammography Operating
SpecificationCharger Input Mono-phase,AC
specificationsProject

Product sourcing keywords

These terms come from the title, visible copy and specifications, and link into matching aggregate pages.

Continue from this detail page into sourcing structure

These links connect the detail page back to category hubs, procurement aggregates and knowledge pages so new inventory is not isolated.

LabInstSource related sourcing paths

Related solutions LabInstSource related paths

Cleanroom Monitoring and Supplies

LabInstSource procurement phrases

LabInstSource related product samples