Product specs

CategoryLaboratory Instruments
Unitset
ModelHM-YDJ
Frequency50/60 Hz
PC supportYes
Output range50–300 kV
CustomizationAvailable
Working modesManual and automatic
CategoryLaboratory Instruments
AvailabilityInquiry required
Source date2026-07-22

Buyer's Digest

Use this page as a product-first sourcing checkpoint before sending an RFQ. Category: Laboratory Instruments. Confirm application fit, capacity, materials, destination, lead time and compliance requirements before comparing suppliers.

Original product description

The HM-YDJ is a high-voltage hipot test instrument described for AC/DC laboratory testing. The system consists of a control console and an oil-filled test transformer.

The tested object connects to the high-voltage output terminal, while the console provides measurement, monitoring, and operating controls through its meters, indicators, buttons, voltage regulator, and protection components.

The test transformer uses a single-frame core structure with the primary winding around the core and the high-voltage winding outside it. This coaxial winding arrangement is described as reducing magnetic flux leakage and improving coupling between the windings.

The single-phase system accepts an adjustable 0–400 V output from the console regulator at the transformer primary to produce an adjustable high-voltage secondary output.

Listed configuration data includes a 50–300 kV output range, 3–300 kVA capacity range, 50/60 Hz frequency, impedance voltage below 12%, no-load current below 4%, surface temperature rise below 55°C, and continuous working time of no more than five minutes.

Manual and automatic working modes are listed, together with PC support, calibration-report support, customization availability, and CE certificate support. The stated transport arrangement is a wooden box with foam inside.

Procurement confirmation: Buyers should confirm whether the selected configuration provides AC output, DC output, or both;the exact rated voltage and capacity;control mode;PC interface and software scope;included accessories;protection settings;measurement accuracy;applicable test standards;calibration-report contents;and the specific CE documentation supplied.

Also confirm the final dimensions, gross weight, input power requirements, duty-cycle conditions, installation needs, and whether the oil-filled transformer is shipped filled and ready for commissioning.

HM-YDJ | Applications and Buyer Notes

HM-YDJ is organized as a sourcing-ready Laboratory Instruments reference. The page combines visible product or company data with structured procurement cues so buyers can compare application fit, specifications, quantity, quality requirements and lead-time que

Applications

  • Initial shortlist building for related product or supplier options.
  • Specification and application fit review before bulk purchasing.
  • Category, keyword and detail-page comparison before sending an RFQ.

Key specifications

Category
Laboratory InstrumentsBased on visible page data; confirm exact value in the RFQ.
Unit
setBased on visible page data; confirm exact value in the RFQ.
Model
HM-YDJBased on visible page data; confirm exact value in the RFQ.
Frequency
50/60 HzBased on visible page data; confirm exact value in the RFQ.
PC support
YesBased on visible page data; confirm exact value in the RFQ.
Output range
50–300 kVBased on visible page data; confirm exact value in the RFQ.
Customization
AvailableBased on visible page data; confirm exact value in the RFQ.
Working modes
Manual and automaticBased on visible page data; confirm exact value in the RFQ.

Buyer tips

  • State quantity range and split-delivery needs before price comparison.
  • Add certification, material or inspection standards when they affect acceptance.
  • For time-sensitive projects, include target arrival date and destination.
  • For special applications, describe operating condition, installation environment and duty cycle.

FAQ

What should buyers confirm first?

Confirm application, specification, quantity, destination and lead-time requirements before comparing offers.

Can buyers inquire when specs are incomplete?

Yes. Add model, material, size, use case and inspection needs in the RFQ to make replies comparable.

How should this listing be evaluated?

Check title, category, specifications and related keywords against the actual sourcing requirement.

Source mix: ugc

Key specifications

CategoryLaboratory Instruments
Unitset
ModelHM-YDJ
Frequency50/60 Hz
PC supportYes
Output range50–300 kV
CustomizationAvailable
Working modesManual and automatic
Capacity range3–300 kVA
Instrument typeAC hipot tester;product listing describes AC/DC hipot testing
No-load currentBelow 4%
Impedance voltageBelow 12%
Calibration reportSupported
Certificate supportCE support listed
Insulating materialOil
Transport packagingWooden box with foam inside
Continuous working timeNo more than 5 minutes
Surface temperature riseBelow 55°C
Primary adjustable voltage0–400 V

Product sourcing keywords

These terms come from the title, visible copy and specifications, and link into matching aggregate pages.

Continue from this detail page into sourcing structure

These links connect the detail page back to category hubs, procurement aggregates and knowledge pages so new inventory is not isolated.

LabInstSource related sourcing paths

LabInstSource procurement phrases

LabInstSource related product samples

Supplier profile

LabInstSource Imported Supplier Pool
主营:Laboratory Instruments

View full profile >