LabInstSourceLab instruments, testing equipment, microscopes, balances, and cleanroom supplies
Factory AC Resonant Hv Hipot Testing Equipment Variable Frequency Series Reactor Customized
Optical Instrument

Factory AC Resonant Hv Hipot Testing Equipment Variable Frequency Series Reactor Customized

Laboratory detail pages should help buyers judge whether one instrument or consumable fits the intended workflow, validation scope and environment before RFQ.

Quote on request

Product sourcing profile

CategoryOptical Instrument
Inquiry workflowPlatform RFQ workflow
AvailabilityInquiry required
Updated2026-05-05

Product introduction

Home Instruments & Meters Test Instrument Test Machine Factory AC Resonant Hv Hipot Testing Equipment Variable Frequency Series Reactor Customized US$1,000.00-5,000.00 1 Piece-sales SerLabInstSource curates RFQ-led product discovery for buyers looking for microscopes options. The page is organized around specification review, application fit, and inquiry-ready comparison.When evaluating this product, buyers should confirm application fit, required performance range, installation environment, lead time, documentation, and whether the supplier can support OEM or project quotations. Current vertical focus: laboratory instrument sourcing, testing equipment discovery, and rfq-ready lab supply platform.

Selection and RFQ points

Review material fit, application context, alternatives and RFQ detail before comparing related product paths.

Material fit Optical Instrument

Confirm material, size, finish, tolerance and processing needs before price comparison.

Application fit application, operating environment and usage frequency

Add the target application and operating context so related products can be compared correctly.

Alternative path Variable Frequency Resonance Testing System

Use nearby materials, equipment types or category pages when this record is close but not exact.

RFQ detail Quantity, destination, timing

Include quantity, destination, target delivery window, packaging and any technical constraints.

LabInstSource quality checks

Workflow contextConfirm whether the item fits the intended lab, QC or cleanroom workflow.

Use this check before moving from discovery into product comparison or RFQ submission.

Validation requirementCheck sample type, accuracy, environment and certification needs before comparing offers.

Use this check before moving from discovery into product comparison or RFQ submission.

Procurement detailBring validation scope, operating environment and documentation requirements into the RFQ.

Use this check before moving from discovery into product comparison or RFQ submission.

Key specifications

CategoryMicroscopes
Brand
Unitset
Accuracy Grade1.5%
After-sales ServiceLife Time
ApplicationIndustrial automation and process control
CYBP-BD-108/108/275kW 27kV/1A four sets(dry type) 5kVA(dry type) 110kV ≤31500kVA 35kV transformer 35kV switch, busbar, PT, CT ect. 10kV(300mm 2 ) cable 2km 35kV(300mm 2 ) cable 0.5km
CYBP-BD-1600/800/20060kW 200kV/2A four sets(oil immersed) 60kVA(dry type) 800kV ≤80000kVA 220kV transformer ≤50000kVA 110kV transformer 500kV GIS, PT, CT ect. 220kV switch, busbar, PT, CT ect. 110kV(400mm 2 ) cable ≤1.5km 220kV(400mm 2 ) cable ≤1.0km
CYBP-BD-200/200/5010kW 50kV/1A four sets(dry type) 10kVA(dry type) 200kV ≤50000kVA 110kV transformer 110KV GIS, PT, CT ect.(preventive test) 35kV(300mm 2 ) cable ≤1.0km 10kV(300mm 2 ) cable ≤2.0km
CYBP-BD-270/270/4515kW 45kV/1A six sets(dry type) 15kVA(dry type) 300kV ≤50000kVA 110kV transformer 110kV GIS, PT, CT ect. 35kV(300mm 2 ) cable ≤1.2km 10kV(300mm 2 ) cable ≤3.0km
CYBP-BD-50/50/253kW 25kV/1A two sets(dry type) 3kVA(dry type) 50kV ≤1000kVA 10kV transformer 10kV switch, busbar, PT, CT ect. 10kV(300mm 2 ) cable≤1.0km
CYBP-BD-800/400/5030kW 50kV/2A eight sets(dry type) 100kV/2A four sets(oil immersed) 30kVA(dry type) 30kA(oil immersed) 400kV ≤80000kVA 220kV transformer ≤50000kVA 110kV transformer 110kV/220kV GIS, PT, CT ect. 35kV(300mm 2 ) cable ≤2.0km 110kV(300mm 2 ) cable ≤0.7km
CategoryMicroscopes
CustomizationAvailable
DisplayDigital
Feature Highlightsdigital
Frequency Adjust Range30Hz-300Hz
Frequency Power SourceResonant Reactor Excitation transformer Divider Application
Frequency adjust sensitivity0.1Hz
Input Power220V/380±10%
Load WayElectronic Load
ModelApplication(10kV~500kV transformer substation AC voltage withstand equipment, frequency 30~300Hz)
Model NO.CYBP-DL
OriginWuhan, China
Output Voltage Waveform Distortion Rate≤1.0%
Output frequency30-300Hz
Power3kw
Power SourceAC380
Power sourceSingle phase 220V or 3 phase 380V ±10%
Product TitleFactory AC Resonant Hv Hipot Testing Equipment Variable Frequency Series Reactor Customized
ProtectionOvervoltage, overcurrent, zero-start and other protective functions
Quality factor30-90
Rated output voltage0-1000kV or under
Resonance voltage waveformSine wave, waveform distortion rate ≤1.0%
SpecificationCustomized
Testing accuracy1.5%
TrademarkUnited
TypeVariable Frequency Resonance Testing System
US$1,000.00-5,000.001 Piece (MOQ)
Voltage220v
Warranty1 Year
Work formContinuous working

Keyword evidence

Only terms with visible evidence in this listing are shown here.

Product sourcing keywords

These terms come from the title, visible copy and specifications, and link into matching aggregate pages.

Related keyword paths

Grouped by the product keyword that generated the related path.

SOURCING DECISION BRIEF

Factory AC Resonant Hv Hipot Testing Equipment Variable Frequency Series Reactor Customized sourcing decision brief

Laboratory detail pages should help buyers judge whether one instrument or consumable fits the intended workflow, validation scope and environment before RFQ.

Category
Microscopes
Price status
Quote on request
Inquiry model
Structured product RFQ with quantity, destination and technical requirements.
Availability
Confirm by inquiry
Sourcing lens
Workflow-fit laboratory decision
Primary compare
Category, Brand, Unit
Adjacent category
Microscopes and Optical Equipment
Next route
Microscopes and Optical Equipment RFQ Tags
Buyer checklist
  • Workflow fit: Confirm sample type, workflow stage and operating environment before supplier outreach.
  • Validation fit: Compare accuracy, documentation and compliance needs before RFQ.
  • Technical handoff: Carry validation scope, environment and documentation requirements into the inquiry.
How should buyers use this LabInstSource detail page?

Use the detail page to confirm one instrument or consumable against the intended workflow before opening an RFQ.

What should buyers compare first?

Compare sample type, accuracy, environment and the nearest procurement or knowledge route.

LabInstSource related sourcing paths

LabInstSource procurement phrases

LabInstSource project-fit checks

Measurement Range Confirm Measurement Range before comparing offers or moving the inquiry forward.
Accuracy Confirm Accuracy before comparing offers or moving the inquiry forward.
Sample Type Confirm Sample Type before comparing offers or moving the inquiry forward.
Certification Confirm Certification before comparing offers or moving the inquiry forward.
Application route Use Application to compare adjacent options instead of relying on one broad title match.
Country route Use Country to compare adjacent options instead of relying on one broad title match.

LabInstSource related product samples

Technical validation sourcing method

Workflow fitReview the instrument or consumable against the target workflow before comparing offers.
Validation contextUse accuracy, sample type and environment requirements to filter low-fit options.
Procurement RFQSend validation, certification and operating-environment details through the inquiry path.

Procurement notes

If visible specifications are still thin, add model, material, interface, quantity, application fit, destination and target lead time before comparing quotes.

Next sourcing actions