LabInstSourceLab instruments, testing equipment, balances, microscopes, cleanroom products, and technical sourcing support for global buyers.
Cleveland Open Cup Apparatus ASTM D92 Auto Cleveland Open Cup Flash Point Testing Equipment
Moisture Analyzers

Cleveland Open Cup Apparatus ASTM D92 Auto Clevel | RFQ Sourcing Details

Moisture Analyzers · Quote on request

This is a product procurement detail page: check specs, images, category context and related sourcing paths before sending an RFQ.

Quote on request

Product specs

CategoryMoisture Analyzers
Unitset
After-sales Service2 Years
ApplicationSchool, Lab
CertificationCE, ISO, RoHS
CustomizedNon-Customized
Detection MethodUV Flash Detector
Environmental Temperature5℃~35℃
CategoryMoisture Analyzers
AvailabilityInquiry required
Updated2026-05-26

Buyer's Digest

Use this page as a product-first sourcing checkpoint before sending an RFQ. Category: Moisture Analyzers. Confirm application fit, capacity, materials, destination, lead time and compliance requirements before comparing suppliers.

Original product description

Automatic COC Flash Point Tester Automatic COC Flash Point Tester is designed, developed and manufacturedaccording to American Standard ASTM D92-05a"Standard Test Method for. Flash and Fire Points by Cleveland Open Cup Tester".

It is suitable for the determination of the flashpoint and fire point of petroleum products by an automated Cleveland opencup apparatus.It is applicable to all petroleum productswith flash points above 79°C (175°F) and below 400°C(752°F) except fuel oils Principle Flash Point: the lowesttemperature corrected to a barometric pressure of 101.3 k.

Pa(760mm Hg), at which application of an ignition source causesthe vapors of a specimen of the sample to ignite under specifiedconditions of test. Fire Point: the lowest temperature corrected to a barometric pressure of 101.3 k.

Pa (760mm Hg), at which application of an ignition source causes thevapors of a test specimen of the sample to ignite and sustainburning for a minimum of 5s under specified conditions oftest. Features 1.Fully Automated Operation: Tests flash/fire points automatically with precision.

Automatic lift arm control, temperature control, ignition, detection, result correction, saving& printing. 7-inch Touchscreen (800×480 pixels) with intuitive English interface. 2.Advanced Ignition & Detection: Electronic Silicon-Carbon Igniter: Flameless, gas-free operation.

UV Flash Detector: Non- , millisecond response. Resistant to oil fumes, no maintenance needed. 3.Efficient & Safe Design: Elevated Heating Chamber with cooling mesh: Prevents instrument overheating. Cools to room temperature within 20 min. Auto-Fire Suppression: Safety cover moves over the cup post-test.

Self-Diagnostics: Tests arm control, ignition, igniter, heater, fan, and extinguisher. Product Parameters Operating voltage AC220V±10%, 50.

Hz(supplied with 110V step up 220V transformer) Operating power 700W Test Range Flash/Fire Point: 79 ~ 400ºC Resolution 0.1ºC Temperature rising rate 5 ~ 17°C/min &5 ~ 6°C/min (auto-switching) Ignition electronic silicon-carbon igniter, electronic flame, no gas source required HMI HD7-inch high resolution LCD touch screen Temperature sensor L-shaped Class-A Pt100 Detailed Photos Structure Automatic COC Flash Point Tester is mainly composed of two parts, which are an electronic control unit (ECU), a flash/fire point test unit.

ECU, installed with switching power supp

Cleveland | Applications and Buyer Notes

Cleveland is organized as a sourcing-ready Moisture Analyzers reference. The page combines visible product or company data with structured procurement cues so buyers can compare application fit, specifications, quantity, quality requirements and lead-time ques

Applications

  • Initial shortlist building for related product or supplier options.
  • Specification and application fit review before bulk purchasing.
  • Category, keyword and detail-page comparison before sending an RFQ.

Key specifications

Category
Moisture AnalyzersBased on visible page data; confirm exact value in the RFQ.
Unit
setBased on visible page data; confirm exact value in the RFQ.
After-sales Service
2 YearsBased on visible page data; confirm exact value in the RFQ.
Application
School, LabBased on visible page data; confirm exact value in the RFQ.
Certification
CE, ISO, RoHSBased on visible page data; confirm exact value in the RFQ.
Customized
Non-CustomizedBased on visible page data; confirm exact value in the RFQ.
Detection Method
UV Flash DetectorBased on visible page data; confirm exact value in the RFQ.
Environmental Temperature
5℃~35℃Based on visible page data; confirm exact value in the RFQ.

Buyer tips

  • State quantity range and split-delivery needs before price comparison.
  • Add certification, material or inspection standards when they affect acceptance.
  • For time-sensitive projects, include target arrival date and destination.
  • For special applications, describe operating condition, installation environment and duty cycle.

FAQ

What should buyers confirm first?

Confirm application, specification, quantity, destination and lead-time requirements before comparing offers.

Can buyers inquire when specs are incomplete?

Yes. Add model, material, size, use case and inspection needs in the RFQ to make replies comparable.

How should this listing be evaluated?

Check title, category, specifications and related keywords against the actual sourcing requirement.

Source mix: ugc

Key specifications

CategoryMoisture Analyzers
Unitset
After-sales Service2 Years
ApplicationSchool, Lab
CertificationCE, ISO, RoHS
CustomizedNon-Customized
Detection MethodUV Flash Detector
Environmental Temperature5℃~35℃
Model NO.GD-3536ZD
Operating Power700W
OriginChongqing, China
PrintingThermal Printer, Automatic Printing
Resolution0.1℃
ServiceEngineers Available to Service Machinery Overseas
StructureDesktop
Test MethodCoc
Test StandardASTM D92
TrademarkGold
Transport PackageStandard Wooden Case and Carton
UsageFlash Point Testing Equipment for Petroleum Produ
Warranty2 Years

Product sourcing keywords

These terms come from the title, visible copy and specifications, and link into matching aggregate pages.

Continue from this detail page into sourcing structure

These links connect the detail page back to category hubs, procurement aggregates and knowledge pages so new inventory is not isolated.

LabInstSource related sourcing paths

LabInstSource procurement phrases

LabInstSource related product samples