LabInstSourceLab instruments, testing equipment, balances, microscopes, cleanroom products, and technical sourcing support for global buyers.
China Equipment Eye Machine Portable Ophthalmic a/B Ultrasound Scan
Autoclaves

China Equipment Eye Machine Portable Ophthalmic a | RFQ Sourcing Details

Autoclaves · Quote on request

This is a product procurement detail page: check specs, images, category context and related sourcing paths before sending an RFQ.

Quote on request

Product specs

CategoryAutoclaves
Unitset
Powerrequirement: AC 100-240V 50-60Hz-Rate
colorLED touch screen. 3
Standardworkstation software, easily for transfer and manage data. 4. Free softw
frequency20 Mhz Resolution: 1um Measurement range: 0.23~1.3mm Accuracy: ±5um
CategoryAutoclaves
AvailabilityInquiry required
Updated2026-05-28

Buyer's Digest

Use this page as a product-first sourcing checkpoint before sending an RFQ. Category: Autoclaves. Confirm application fit, capacity, materials, destination, lead time and compliance requirements before comparing suppliers.

Original product description

Ophthalmic scanner ODU1 Series We supply Ophthalmic A/B Scan for many years,we devoted ourselves to send you clients high quality Clinical E quipment with long terms services . We are expecting to become your long-terms business partner in China.

Introduc tion of Palm Ultrasound Scanner ODU1 Series: Due to the special anatomical structure of the eyeball, real-time three-dimensional reconstruction is required during the examination. The location of the lesion and the relationship between the lesion and the surrounding tissue can be determined .

Standard Configuration of Palm Ultrasound Scanner ODU1 Series : OD1-A OD1-P OD1-AP 1 Main unit. Main unit. Main unit. 2 10.0MHz A probe. 20MHz Angled Probe 10.0MHz A probe. 20MHz Angled Probe 3 Power Adapter. Power Adapter. Power Adapter.

4 Gage block for A-Scan/Biometer Gage block for A-Scan/Biometer Two kinds of Gage blocks 5 Touch screen pen. Touch screen pen. Touch screen pen.

Biometer: Probe Frequency: 10 Mhz Resolution: 0.01mm Accuracy: ±0.02mm Gain adjustable: 0-120dB Measurement range: 15~35 mm (vel 1640m/s) Measurements: ACD, Lens, Vitreous, and AXL Examination modes: Normal, Aphakic, pseudophakic and dense cataract Measurement mode: immersion and , auto and manual IOL formulas: SRK-II,SRK-T,BINKHORST,HOLLADAY,HOFFER-Q,HAIGIS Power requirement: AC 100-240V 50-60.

Hz | Rate power:

China | Applications and Buyer Notes

China is organized as a sourcing-ready Autoclaves reference. The page combines visible product or company data with structured procurement cues so buyers can compare application fit, specifications, quantity, quality requirements and lead-time questions before

Applications

  • Initial shortlist building for related product or supplier options.
  • Specification and application fit review before bulk purchasing.
  • Category, keyword and detail-page comparison before sending an RFQ.

Key specifications

Category
AutoclavesBased on visible page data; confirm exact value in the RFQ.
Unit
setBased on visible page data; confirm exact value in the RFQ.
Power
requirement: AC 100-240V 50-60Hz-RateBased on visible page data; confirm exact value in the RFQ.
color
LED touch screen. 3Based on visible page data; confirm exact value in the RFQ.
Standard
workstation software, easily for transfer and manage data. 4. Free softwBased on visible page data; confirm exact value in the RFQ.
frequency
20 Mhz Resolution: 1um Measurement range: 0.23~1.3mm Accuracy: ±5umBased on visible page data; confirm exact value in the RFQ.

Buyer tips

  • State quantity range and split-delivery needs before price comparison.
  • Add certification, material or inspection standards when they affect acceptance.
  • For time-sensitive projects, include target arrival date and destination.
  • For special applications, describe operating condition, installation environment and duty cycle.

FAQ

What should buyers confirm first?

Confirm application, specification, quantity, destination and lead-time requirements before comparing offers.

Can buyers inquire when specs are incomplete?

Yes. Add model, material, size, use case and inspection needs in the RFQ to make replies comparable.

How should this listing be evaluated?

Check title, category, specifications and related keywords against the actual sourcing requirement.

Source mix: ugc

Key specifications

CategoryAutoclaves
Unitset
Powerrequirement: AC 100-240V 50-60Hz-Rate
colorLED touch screen. 3
Standardworkstation software, easily for transfer and manage data. 4. Free softw
frequency20 Mhz Resolution: 1um Measurement range: 0.23~1.3mm Accuracy: ±5um

Product sourcing keywords

These terms come from the title, visible copy and specifications, and link into matching aggregate pages.

Continue from this detail page into sourcing structure

These links connect the detail page back to category hubs, procurement aggregates and knowledge pages so new inventory is not isolated.

LabInstSource related sourcing paths

LabInstSource procurement phrases

LabInstSource related product samples