LabLineSourceLab instruments, testing equipment, microscopes, balances, and cleanroom supplies
Automatic Gas Chromatography Equipment Auto Injector / Sampler , GC650 Gas Analysis Equipment
Analysis Instrument

Automatic Gas Chromatography Equipment Auto Injector / Sampler , GC650 Gas Analysis Equipment

Laboratory detail pages should help buyers judge whether one instrument or consumable fits the intended workflow, validation scope and environment before RFQ.

Quote on request

Product sourcing profile

CategoryAnalysis Instrument
Inquiry workflowPlatform RFQ workflow
AvailabilityInquiry required
Updated2026-05-03

Product introduction

Detailed Product Description High Light: analyse de chromatographie en phase gazeuse , machine de chromatographie en phase gazeuse Automatic Gas Chromatography Equipment Inlet System , GC650 Gas Analysis Equipment GC650 5 kinds of sample injectors and all convLabLineSource curates RFQ-led product discovery for buyers looking for chromatography systems options. The page is organized around specification review, application fit, and inquiry-ready comparison.When evaluating this product, buyers should confirm application fit, required performance range, installation environment, lead time, documentation, and whether the supplier can support OEM or project quotations. Current vertical focus: laboratory instrument sourcing, testing equipment discovery, and rfq-ready lab supply platform.chromatograph

Selection and RFQ points

Review material fit, application context, alternatives and RFQ detail before comparing related product paths.

Material fit Automatic Gas Chromatography Equipment

Confirm material, size, finish, tolerance and processing needs before price comparison.

Application fit application, operating environment and usage frequency

Add the target application and operating context so related products can be compared correctly.

Alternative path Gas Analysis Equipment

Use nearby materials, equipment types or category pages when this record is close but not exact.

RFQ detail Quantity, destination, timing

Include quantity, destination, target delivery window, packaging and any technical constraints.

LabLineSource quality checks

Workflow contextConfirm whether the item fits the intended lab, QC or cleanroom workflow.

Use this check before moving from discovery into product comparison or RFQ submission.

Validation requirementCheck sample type, accuracy, environment and certification needs before comparing offers.

Use this check before moving from discovery into product comparison or RFQ submission.

Procurement detailBring validation scope, operating environment and documentation requirements into the RFQ.

Use this check before moving from discovery into product comparison or RFQ submission.

Key specifications

Vertical Sitelablinesource
CategoryChromatography Systems
Source Domainatomicspectrometer.com
BrandPG instruments
Unitset
Accuracy±2% full scale
Analog signal voltage ranges±10,5,2.5,1.25V
Analog to digital conversion resolution21 bits at all sampling rates
ApplicationFood and beverage processing
Bead CurrentAuto Optimization
Brand NamePG instruments
Bridge Power SupplyConstant current system-400mA
Capacity1.8ml
Capillary InletHigh resolution, prompt analysis time and most typical inlet system
CategoryChromatography Systems
CellFlow through , 4 Rhenium/tungsten filaments (32/each)
CertificationCE
ColumnIdeal for use with capillary columns
Cooling RateAbout 6 minutes 300℃ to 50℃
Custom reportsPeak number, retention time, peak name, peak area, peak height, area%, height%, peak start time, theoretical plates, capacity factor, peak resolution, peak asymmetry, regression coefficient value, correlation coefficient value, standard deviation, weight f
Data ManagementData export results as Text files;Dynamic data exchange to Microsoft windows applications;Various data management techniques support the time event programming (17items).
Data VisualizationUp to chromatograms in real time, zoom/unzoom at any time;Scrutinize focused peaks, display baseline;Chromatograms overlap, background subtraction.
Dimensions425mm(W)*555mm(D)*450mm(H)
Dynamic range>2*10 6
EPC controlInlets and detectors-up and combustion gases
Electrode Voltage260V
External event I/O ports8
FID air0-500 mL/min
FID hydrogen0-100 mL/min
FID/NPD make-up0-100 mL/min
FPD air0-250 mL/min
FPD hydrogen0-300 mL/min
FPD make-up0-130 mL/min
Feature Highlightspneumatic, digital, automatic
FeaturesElectrically heated, alkali-impregnated thermionic surface in chemically reactive H2-Air environment
Filament Protection circuitAutomatically protect from over load and over current
Flow resolution0.01mL/min
Gas Sampling Valve4 Valves can be controlled by Air Actuation
Heating RateAbout 2.3 minutes 50℃ to 300℃
High Lightanalyse de chromatographie en phase gazeuse , machine de chromatographie en phase gazeuse
IPC flow range0 to 500mL/min
IPC pressure range0 to 100psi
Inner volume16.25 liter (250mm W* 260mm D*250mm H)
Internal Volume20uL
Jet TipMade by Quartz and supplied with-260V for excellent ion collection
Linear Programming RateMax: 120℃/min up to 450℃/min (0.1℃ increment)
Linearity10 7
Matched Termschromatograph
Maximum installed Qty.2
Minimum Order Quantity1 unit
Model NumberGC650
PG Instruments Limited Global Manufacturer of Analytical InstrumSales & Support Request A Quote
Packaging DetailsCarton package
Packed Inlet1/4", 1/8" Glass-lined Metal Liner are available.
Payment TermsT/T,L/C
Power220V, 50/60Hz, 2.5kW
Pressure100psi
Pressure resolution0.01psi
Pressure/flow programming stepsup to 5 steps
Product TitleAutomatic Gas Chromatography Equipment Auto Injector / Sampler , GC650 Gas Analysis Equipment
RemoteStart, stop control independent
Repeatability±0.05psi
ResponseN, P specific
Response Time0.5 seconds
Run TimeAutomatically computed to 999.9 minutes by 0.1 minute increments
Sampling RateUser selectable 10-60Hz per channel
Sensitivity>9 mCoulomb/g Carbon (for C 3 H 8 )
Specificityat H2=3mL/min
Split ratioup to 5000:1
Supply Ability400 units per year
Support IPC ChannelsUp to 20, for inlets, detectors or auxiliary gases (including pressure channel)
TCD make-up0-12 mL/min
TCD reference0-100 mL/min
TID-EC mode (O2 mode)Selective Detection for N, P, oxygenated and nitro compounds
TID-NO mode (N2 mode)Selective Detection for N, P, halogenated and electronegative compounds
TID-NP mode (NPD mode)Selective Detection for N and P
Temp. Programming20 Step
Temp. RangeAmbient to 450℃
Temp. coefficient±0.01psi/℃
Temperature RangeAmbient to 450℃-100℃ to 450℃ by using a cryogenic valve
Thermionic SourceRigid Rb/Cs/Sr-ceramic surface on Ni-ceramic sublayer
TypePacked column inlet, Septum purge Packed column Inlet, Capillary Column Inlet, GSV, Auto Gas Sampling System and etc.
VariabilityCan be used TID by exchanging the bead and collector
Voltage1.25v
Weight30Kg

Keyword evidence

Only terms with visible evidence in this listing are shown here.

Product sourcing keywords

These terms come from the title, visible copy and specifications, and link into matching aggregate pages.

Related keyword paths

Grouped by the product keyword that generated the related path.

SOURCING DECISION BRIEF

Automatic Gas Chromatography Equipment Auto Injector / Sampler , GC650 Gas Analysis Equipment sourcing decision brief

Laboratory detail pages should help buyers judge whether one instrument or consumable fits the intended workflow, validation scope and environment before RFQ.

Category
Chromatography Systems
Price status
Quote on request
Inquiry model
Structured product RFQ with quantity, destination and technical requirements.
Availability
Confirm by inquiry
Sourcing lens
Workflow-fit laboratory decision
Primary compare
Vertical Site, Category, Source Domain
Adjacent category
Sample Preparation and Lab Basics
Next route
Measurement Range Sample Preparation and Lab Basics
Buyer checklist
  • Workflow fit: Confirm sample type, workflow stage and operating environment before supplier outreach.
  • Validation fit: Compare accuracy, documentation and compliance needs before RFQ.
  • Technical handoff: Carry validation scope, environment and documentation requirements into the inquiry.
How should buyers use this LabLineSource detail page?

Use the detail page to confirm one instrument or consumable against the intended workflow before opening an RFQ.

What should buyers compare first?

Compare sample type, accuracy, environment and the nearest procurement or knowledge route.

LabLineSource related sourcing paths

LabLineSource procurement phrases

LabLineSource project-fit checks

Measurement Range Confirm Measurement Range before comparing offers or moving the inquiry forward.
Accuracy Confirm Accuracy before comparing offers or moving the inquiry forward.
Sample Type Confirm Sample Type before comparing offers or moving the inquiry forward.
Certification Confirm Certification before comparing offers or moving the inquiry forward.
Application route Use Application to compare adjacent options instead of relying on one broad title match.
Country route Use Country to compare adjacent options instead of relying on one broad title match.

LabLineSource related product samples

Technical validation sourcing method

Workflow fitReview the instrument or consumable against the target workflow before comparing offers.
Validation contextUse accuracy, sample type and environment requirements to filter low-fit options.
Procurement RFQSend validation, certification and operating-environment details through the inquiry path.

Procurement notes

If visible specifications are still thin, add model, material, interface, quantity, application fit, destination and target lead time before comparing quotes.

Next sourcing actions