LabInstSourceLab instruments, testing equipment, balances, microscopes, cleanroom products, and technical sourcing support for global buyers.
AU-120WG Modulus of Sodium Silicate Tester, Water Glass Modulus Meter, Water Glass Modulus Tester
Incubators

AU-120WG Modulus of Sodium Silicate Tester, Water | RFQ Sourcing Details

Incubators · Quote on request

This is a product procurement detail page: check specs, images, category context and related sourcing paths before sending an RFQ.

Quote on request

Product specs

CategoryIncubators
Unitset
TypeLiquid Density Meter
UsageSodium Silicate Modulus Density Resolution: 0.0001g/cm3 Modulus resolution: 0.01M
Warranty2 Years;Life-Long Maintenance Density Meter
CertificationCE, FCC
CategoryIncubators
AvailabilityInquiry required
Updated2026-05-28

Buyer's Digest

Use this page as a product-first sourcing checkpoint before sending an RFQ. Category: Incubators. Confirm application fit, capacity, materials, destination, lead time and compliance requirements before comparing suppliers.

Original product description

Modulus of Sodium Silicate Tester, Water Glass Modulus Meter, Water Glass Modulus Tester Application light industry,textile industry,foundry industry,refractory materials,papermaking,fine ceramics,civil engineering,chemical engineering system,mechanical industry,building industry,agriculture, cleaning industry.,etc.

In accordance with GB/T standards,the series products according to Archimedes principle buoyancy method.it is the new type sodium silicate modulus and density tester that has been researched and density SG,modulus M,baume Bé can be tested accura s series is sodium metasilicate, Na2. SiO3.

Also known as waterglass or liquid glass, these materials are available in aqueous solution and in solid form. The pure compositions are colourless or white, but commercial samples are often greenish or blue owing to the presence of iron-containing impurities.

The modulus M of sodium silicate is determined by the proportioning of quartz sand and alkaline, i.e. molar ratio of SiO2 and Na2O, modulus that displays the composition of sodium silicate is one of important parameter, and is commonly between 1.5 and 3.5.

The larger the modulus is, and the more difficult the solid sodium silicate solves in water. the content of water glass in water solution is indicated by density or baume.Viscosity of water glass is closely related to modulus,concentration and temperature.

Technical Parameters (1) AU-300WG modulus resolution:0.1M,baume resolution:0.01Bé ,density resolution:0.001g/cm3 (2) AU-120WG modulus resolution:0.01M,baume resolution:0.001Bé,density resolution:0.0001g/cm3 Features 1. Density,modulus,baume can be read directly. 2.

High precision,simple operation,stability and durability. 3. Dynamic measuring,density value can be updated along with liquid formula. 4. Function of water temperature setting and air buoyancy density compensation setting. 5. Function of buzzer warning and overload warning. 6.

Including RS-232C interface.it is convenient to connect PC with printer.AU-40 can be chose to print data. 7. Equiped with special windproof dustproof cover,convenient structure,sturdy and durable. 8.

Volatile liquid,corrosive liquid,viscous liquid,strong acid and strong base liquid can be measured quickly(relative accessori

AU-120WG | Applications and Buyer Notes

AU-120WG is organized as a sourcing-ready Incubators reference. The page combines visible product or company data with structured procurement cues so buyers can compare application fit, specifications, quantity, quality requirements and lead-time questions bef

Applications

  • Initial shortlist building for related product or supplier options.
  • Specification and application fit review before bulk purchasing.
  • Category, keyword and detail-page comparison before sending an RFQ.

Key specifications

Category
IncubatorsBased on visible page data; confirm exact value in the RFQ.
Unit
setBased on visible page data; confirm exact value in the RFQ.
Type
Liquid Density MeterBased on visible page data; confirm exact value in the RFQ.
Usage
Sodium Silicate Modulus Density Resolution: 0.0001g/cm3 Modulus resolution: 0.01Based on visible page data; confirm exact value in the RFQ.
Warranty
2 Years;Life-Long Maintenance Density MeterBased on visible page data; confirm exact value in the RFQ.
Certification
CE, FCCBased on visible page data; confirm exact value in the RFQ.

Buyer tips

  • State quantity range and split-delivery needs before price comparison.
  • Add certification, material or inspection standards when they affect acceptance.
  • For time-sensitive projects, include target arrival date and destination.
  • For special applications, describe operating condition, installation environment and duty cycle.

FAQ

What should buyers confirm first?

Confirm application, specification, quantity, destination and lead-time requirements before comparing offers.

Can buyers inquire when specs are incomplete?

Yes. Add model, material, size, use case and inspection needs in the RFQ to make replies comparable.

How should this listing be evaluated?

Check title, category, specifications and related keywords against the actual sourcing requirement.

Source mix: ugc

Key specifications

CategoryIncubators
Unitset
TypeLiquid Density Meter
UsageSodium Silicate Modulus Density Resolution: 0.0001g/cm3 Modulus resolution: 0.01M
Warranty2 Years;Life-Long Maintenance Density Meter
CertificationCE, FCC

Product sourcing keywords

These terms come from the title, visible copy and specifications, and link into matching aggregate pages.

Continue from this detail page into sourcing structure

These links connect the detail page back to category hubs, procurement aggregates and knowledge pages so new inventory is not isolated.

LabInstSource related sourcing paths

LabInstSource procurement phrases

LabInstSource related product samples