LabLineSourceLab instruments, testing equipment, microscopes, balances, and cleanroom supplies
AC Series Class II A2 Biological Safety Cabinet
Optical Instrument

AC Series Class II A2 Biological Safety Cabinet

Laboratory detail pages should help buyers judge whether one instrument or consumable fits the intended workflow, validation scope and environment before RFQ.

Quote on request

Product sourcing profile

CategoryOptical Instrument
Inquiry workflowPlatform RFQ workflow
AvailabilityInquiry required
Updated2026-05-03

Product introduction

more products Products Clinical Analytical Instruments Biochemistry Analyzer Biochemistry Reagent ELISA Equipment ELISA Kit ESR Analyzer Coagulation Analyzer Hematology Analyzer Urine Analyzer Electrolyte Analyzer Blood Gas Electrolyte Analyzer Nucleic Acid ExLabLineSource curates RFQ-led product discovery for buyers looking for microscopes options. The page is organized around specification review, application fit, and inquiry-ready comparison.When evaluating this product, buyers should confirm application fit, required performance range, installation environment, lead time, documentation, and whether the supplier can support OEM or project quotations. Current vertical focus: laboratory instrument sourcing, testing equipment discovery, and rfq-ready lab supply platform.lab equipmenttest chamberchromatographlaboratory

Selection and RFQ points

Review material fit, application context, alternatives and RFQ detail before comparing related product paths.

Material fit Optical Instrument

Confirm material, size, finish, tolerance and processing needs before price comparison.

Application fit application, operating environment and usage frequency

Add the target application and operating context so related products can be compared correctly.

Alternative path Lab Equipment

Use nearby materials, equipment types or category pages when this record is close but not exact.

RFQ detail Quantity, destination, timing

Include quantity, destination, target delivery window, packaging and any technical constraints.

LabLineSource quality checks

Workflow contextConfirm whether the item fits the intended lab, QC or cleanroom workflow.

Use this check before moving from discovery into product comparison or RFQ submission.

Validation requirementCheck sample type, accuracy, environment and certification needs before comparing offers.

Use this check before moving from discovery into product comparison or RFQ submission.

Procurement detailBring validation scope, operating environment and documentation requirements into the RFQ.

Use this check before moving from discovery into product comparison or RFQ submission.

Key specifications

Vertical Sitelablinesource
CategoryMicroscopes
Source Domainbiobase.com
Brandbiobase.com
Unitset
Airflow System70% air recirculation, 30% air exhaust
ApplicationLaboratory and analytical workflows
CasterFootmaster caster
CategoryMicroscopes
Consumption600W 800W 1300W 1300W 1700W
Control SystemMicroprocessor
DisplayLCD display: exhaust filter and downflow filter pressure, filter and UV lamp working time, inflow and downflow velocity, filter life, humidity and temperature, system working time etc.
Downflow Velocity0.33±0.025m/s
External Size(W*D*H)1100*755*2200mm 1300*755*2200mm 1500*755*2200mm 1800*755*2200mm 1950*775*2200mm
Feature Highlightsautomatic, cleanroom
Front WindowMotorized. Two-layer laminated toughened glass≥6mm. Anti UV
Gross Weight270kg 310kg 335kg 395kg 420kg
Illumination≥1000Lux
Inflow Velocity0.53±0.025m/s
Internal Size(W*D*H)940*600*660mm 1150*600*660mm 1350*600*660mm 1625*600*660mm 1800*600*660mm
LED Lamp12W*2 14W*2 16W*2 16W*2 12W*4
Matched Termslab equipment, test chamber, chromatograph, laboratory
MaterialWork Zone: 304 stainless steel
Max Opening480mm
ModelBSC-1100IIA2-X BSC-1300IIA2-X BSC-1500IIA2-X BSC-1800IIA2-X BSC-2000IIA2-X
Noise≤65dB
Optional AccessoryWater and gas tap, Electric height adjustable base stand, Armrest
Package Size(W*D*H)1230*990*1840mm 1430*990*1840mm 1630*990*1840mm 1930*990*1840mm 2080*990*1840mm
Power30w
Power SupplyAC220V, 50/60Hz;110V, 60Hz
Product TitleAC Series Class II A2 Biological Safety Cabinet
Standard AccessoryLED lamp 2pcs-2000IIA2-X 4pcs) , UV lamp 2pcs, Base stand, Remote control, Foot switch, Drain valve, Waterproof socket 2pcs
Tested OpeningSafety height 200mm(8")
ULPA FilterTwo, 99.9995% efficiency at 0.12μm, filter life indicator
UV Lamp30W*1 30W*1 40W*1 40W*1 40W*1
Visual and Audio AlarmAbnormal airflow velocity, filter replacement, front window at unsafe height, high filter pressure alarm, abnormal power failure
Waterproof SocketTwo, total load of two sockets: 500W
Work Surface Height770mm(Can be customized) 800mm(Can be customized)

Keyword evidence

Only terms with visible evidence in this listing are shown here.

Product sourcing keywords

These terms come from the title, visible copy and specifications, and link into matching aggregate pages.

Related keyword paths

Grouped by the product keyword that generated the related path.

SOURCING DECISION BRIEF

AC Series Class II A2 Biological Safety Cabinet sourcing decision brief

Laboratory detail pages should help buyers judge whether one instrument or consumable fits the intended workflow, validation scope and environment before RFQ.

Category
Microscopes
Price status
Quote on request
Inquiry model
Structured product RFQ with quantity, destination and technical requirements.
Availability
Confirm by inquiry
Sourcing lens
Workflow-fit laboratory decision
Primary compare
Vertical Site, Category, Source Domain
Adjacent category
Analytical Instruments
Next route
Microscopes and Optical Equipment RFQ Tags
Buyer checklist
  • Workflow fit: Confirm sample type, workflow stage and operating environment before supplier outreach.
  • Validation fit: Compare accuracy, documentation and compliance needs before RFQ.
  • Technical handoff: Carry validation scope, environment and documentation requirements into the inquiry.
How should buyers use this LabLineSource detail page?

Use the detail page to confirm one instrument or consumable against the intended workflow before opening an RFQ.

What should buyers compare first?

Compare sample type, accuracy, environment and the nearest procurement or knowledge route.

LabLineSource related sourcing paths

LabLineSource procurement phrases

LabLineSource project-fit checks

Measurement Range Confirm Measurement Range before comparing offers or moving the inquiry forward.
Accuracy Confirm Accuracy before comparing offers or moving the inquiry forward.
Sample Type Confirm Sample Type before comparing offers or moving the inquiry forward.
Certification Confirm Certification before comparing offers or moving the inquiry forward.
Application route Use Application to compare adjacent options instead of relying on one broad title match.
Country route Use Country to compare adjacent options instead of relying on one broad title match.

LabLineSource related product samples

Technical validation sourcing method

Workflow fitReview the instrument or consumable against the target workflow before comparing offers.
Validation contextUse accuracy, sample type and environment requirements to filter low-fit options.
Procurement RFQSend validation, certification and operating-environment details through the inquiry path.

Procurement notes

If visible specifications are still thin, add model, material, interface, quantity, application fit, destination and target lead time before comparing quotes.

Next sourcing actions