AA500F Flame AA System 0.1, 0.2, 0.4, 1.0, 2.0nm Atomic Absorption Spectrophotometer
Analysis Instrument

AA500F Flame AA System 0.1, 0.2, 0.4, 1.0, 2.0nm Atomic Absorption Spectrophotometer

Laboratory detail pages should help buyers judge whether one instrument or consumable fits the intended workflow, validation scope and environment before RFQ.

Quote on request

Product sourcing profile

CategoryAnalysis Instrument
Inquiry workflowPlatform RFQ workflow
AvailabilityInquiry required
Updated2026-05-03

Product introduction

Detailed Product Description High Light: UV Visible Spectroscopy , Heavy Metal Analyzer Flame AA System AA500F 0.1, 0.2, 0.4, 1.0, 2.0nm Atomic Absorption Spectrophotometer The flame atomizer offers three flame options: Air/Acetylene is the standard configuratLabLineSource curates RFQ-led product discovery for buyers looking for spectrometers options. The page is organized around specification review, application fit, and inquiry-ready comparison.When evaluating this product, buyers should confirm application fit, required performance range, installation environment, lead time, documentation, and whether the supplier can support OEM or project quotations. Current vertical focus: laboratory instrument sourcing, testing equipment discovery, and rfq-ready lab supply platform.spectrometerlaboratorypipette

Selection and RFQ points

Review material fit, application context, alternatives and RFQ detail before comparing related product paths.

Material fit Flame Aa System

Confirm material, size, finish, tolerance and processing needs before price comparison.

Application fit application, operating environment and usage frequency

Add the target application and operating context so related products can be compared correctly.

Alternative path Analysis Instrument

Use nearby materials, equipment types or category pages when this record is close but not exact.

RFQ detail Quantity, destination, timing

Include quantity, destination, target delivery window, packaging and any technical constraints.

LabLineSource quality checks

Workflow contextConfirm whether the item fits the intended lab, QC or cleanroom workflow.

Use this check before moving from discovery into product comparison or RFQ submission.

Validation requirementCheck sample type, accuracy, environment and certification needs before comparing offers.

Use this check before moving from discovery into product comparison or RFQ submission.

Procurement detailBring validation scope, operating environment and documentation requirements into the RFQ.

Use this check before moving from discovery into product comparison or RFQ submission.

Key specifications

Vertical Sitelablinesource
CategorySpectrometers
Source Domainatomicspectrometer.com
Brand
Unitset
Analytical methodsFlame AA, Flame AE, Graphite Furnace, Hydride Generation
ApplicationFood and beverage processing
Atomizer selectionAutomatic changeover (AA500FG)
Background correctionDeuterium Arc (D2) 1.0Abs, Self Reversal (SR) 3.0Abs
Bandwidth0.1, 0.2, 0.4, 1.0, 2.0, 5.0nm
Baseline stability0.005A/30min
Blazed wavelength250nm
Burner headsTitanium alloy
Capacity75kg
CategorySpectrometers
CertificationCE
Characteristic concentrationCu
Data storageAnalytical results, instrument and measurement parameters, signal profile, calibration curve
Detection limitCu
Dimensions110x54x54cm
Feature Highlightsaluminum, automatic, precision
Flame typesAir/Acetylene, Nitrous Oxide/Acetylene, Air/Propane (LPG)
Focus300nm
Graphite power supply220Vac 50/60hz instantaneous power 5KW current rating
Grating1800 grooves/mm diffraction grating
High LightUV Visible Spectroscopy , Heavy Metal Analyzer
Light sourceHollow cathode lamp (HCL), Deuterium Arc lamp (D2)
Main unit220Vac 50/60hz 200W
Matched Termsspectrometer, laboratory, pipette
Minimum Order Quantity1 unit
Model NumberAA500F Atomic Absorption Spectrometer
ModulationSquare wave pulse
Modulation frequency100hz self reversal (SR) background, 400hz Deuterium Arc (D2) background
NebulizerHigh efficiency glass, Acid proof available as an option
Operating programAA Win Pro software
PG Instruments Limited Global Manufacturer of Analytical InstrumSales & Support Request A Quote
Packaging DetailsCarton package
Payment TermsT/T, L/C
Photometric typeSingle beam
Place of OriginChina
Power200w
Pre-mix chamberCorrosion resistant
Product TitleAA500F Flame AA System 0.1, 0.2, 0.4, 1.0, 2.0nm Atomic Absorption Spectrophotometer
Readout ModeContinuous, manual, peak height, peak area
Safety featuresBurner identification, flame sensor, gas leak sensor, low gas pressure sensor, drain trap sensor, power loss protection
Scan modeAutomatic
Sensitivity (Cu)2μg/ml Absorption >0.280Abs
Stray light≤0.12%T(220nm NaI, 340nm NaNO2)
Supply Ability1500 units per year
Wavelength accuracy+0.15nm
Wavelength range190-900nm
Wavelength resolution0.2nm+0.02nm
calibrationsMulti-standard calibration, standard addition, interpolation
repeatabilityCu

Keyword evidence

Only terms with visible evidence in this listing are shown here.

Product sourcing keywords

These terms come from the title, visible copy and specifications, and link into matching aggregate pages.

Related keyword paths

Grouped by the product keyword that generated the related path.

SOURCING DECISION BRIEF

AA500F Flame AA System 0.1, 0.2, 0.4, 1.0, 2.0nm Atomic Absorption Spectrophotometer sourcing decision brief

Laboratory detail pages should help buyers judge whether one instrument or consumable fits the intended workflow, validation scope and environment before RFQ.

Category
Spectrometers
Price status
Quote on request
Inquiry model
Structured product RFQ with quantity, destination and technical requirements.
Availability
Confirm by inquiry
Sourcing lens
Workflow-fit laboratory decision
Primary compare
Vertical Site, Category, Source Domain
Adjacent category
Sample Preparation and Lab Basics
Next route
Sample Preparation and Lab Basics RFQ Tags
Buyer checklist
  • Workflow fit: Confirm sample type, workflow stage and operating environment before supplier outreach.
  • Validation fit: Compare accuracy, documentation and compliance needs before RFQ.
  • Technical handoff: Carry validation scope, environment and documentation requirements into the inquiry.
How should buyers use this LabLineSource detail page?

Use the detail page to confirm one instrument or consumable against the intended workflow before opening an RFQ.

What should buyers compare first?

Compare sample type, accuracy, environment and the nearest procurement or knowledge route.

LabLineSource related sourcing paths

LabLineSource procurement phrases

LabLineSource project-fit checks

Measurement Range Confirm Measurement Range before comparing offers or moving the inquiry forward.
Accuracy Confirm Accuracy before comparing offers or moving the inquiry forward.
Sample Type Confirm Sample Type before comparing offers or moving the inquiry forward.
Certification Confirm Certification before comparing offers or moving the inquiry forward.
Application route Use Application to compare adjacent options instead of relying on one broad title match.
Country route Use Country to compare adjacent options instead of relying on one broad title match.

LabLineSource related product samples

Technical validation sourcing method

Workflow fitReview the instrument or consumable against the target workflow before comparing offers.
Validation contextUse accuracy, sample type and environment requirements to filter low-fit options.
Procurement RFQSend validation, certification and operating-environment details through the inquiry path.

Procurement notes

If visible specifications are still thin, add model, material, interface, quantity, application fit, destination and target lead time before comparing quotes.

Next sourcing actions